跳至主要内容
临床试验/NCT05131308
NCT05131308已完成不适用

Comparison of the Efficacy of Successful Leak Closure Between Available Leak Closure Methods for Clinically Relevant and Persisting Leaks Arising After Incomplete LAAC: Insights From the LAA-Leak Registry

Kansas City Heart Rhythm Research Foundation1 个研究点 分布在 1 个国家目标入组 160 人开始时间: 2015年1月11日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
160
试验地点
1
主要终点
Size of PDL After Leak Closure Procedure

研究概览

简要总结

Closure of peri-device leaks (PDL) after incomplete LAAC have shown early feasibility, however no comparison study of all the leak closure modalities exists. Therefore, this is an attempt to report the first 3-way observational comparison study to date, with results in 160 total patients in 3 arms including detachable embolization coils, vascular plugs/septal occluders and Radiofrequency ablation.

详细描述

Left Atrial Appendage (LAA) Closure (LAAC) is a potent technique of LAA isolation and exclusion for stroke prevention in patients with atrial fibrillation, with evidence from the PROTECT-AF and PREVAIL-AF trials, including their 5-year follow-up assessments, solidifying LAAC as a viable option in these patients with comparable stroke reduction in comparison to oral anticoagulation (OAC) as well as a reduction in bleeding risk, hemorrhagic CVA, and mortality. However, the surge in the multiple methods of LAA exclusion has also brought to attention postprocedural complications specific to LAAC, namely, peri-device leaks (PDL). The stroke implication and classification of PDL itself still lacks consensus, with an increased thromboembolic (TE) potential due to PDL seen in patients with LARIAT and surgical ligation procedures, yet no statistically significant relationship seen in percutaneous and endocardial LAA closure approaches. PDL > 5mm has been widely accepted as clinically significant, although there remains limited data with no current established guidelines. Placement of a septal occluder device such as Amplatzer Vascular Plug, Detachable embolization coils, Gore Cardioform Septal Occluder (CSO; W.L. Gore and Associates, Newark DE), and radiofrequency ablation (RFA) have all emerged as options to resolve residual PDL and post-surgical/ligation leaks. However, there exists no head-to-head comparison between these modalities. Given their emergence, this is a proposed a multi-center observational study to further assess and evaluate these three treatment modalities for their efficacy for leak closure, assessment of pre-, peri- and post-procedural characteristics after leak closure, TE events, and bleeding risk, and complication rates.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients at risk for stroke or thromboembolism that demonstrated any degree of the significant leak on follow up TEE imaging at least 4-6 weeks following either epicardial, endocardial, or surgical LAAC
  • Patients undergoing any form of eccentric or centric/central leak closure with available modalities (detachable embolization coils, vascular plus/septal/ASD occluders, or RF Ablation). Criteria for this was made based on the judgement of the operator, with no specific cutoffs for leak size, follow-up time from LAAC to leak closure, etc)
  • Age greater than 18 years

排除标准

  • Patients not undergoing leak closure after incomplete LAAC
  • Patients unable to complete 45 day follow-up imaging for reevaluation of LAA leak
  • Patients unable to consent

结局指标

主要结局

Size of PDL After Leak Closure Procedure

时间窗: Immediate postprocedural and 1 year follow-up

Size of leak in mm on TEE after leak closure procedure, immediately at the end of the procedure and at 1 year follow-up

次要结局

  • Periprocedural Complications Occurring From Postoperative Day 0 - Day 7(From postoperative day 0 to day 7)
  • Delayed Procedure-related Complications at 1 Year Follow-up(1 year after procedure)

研究者

发起方
Kansas City Heart Rhythm Research Foundation
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验