跳至主要内容
临床试验/NCT06737614
NCT06737614招募中不适用

Can Pulse Pressure Assessment at the Bedside Detect Low Values or Track Changes of Stroke Volume in Critically Ill Patients? The Multicenter, Cross-sectional, Observational, ANDROMEDA-PEGASUS Study

Pontificia Universidad Catolica de Chile3 个研究点 分布在 3 个国家目标入组 1,500 人开始时间: 2025年5月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
1,500
试验地点
3
主要终点
Left ventricular outflow tract velocity time integral

研究概览

简要总结

The goal of this study is to assess the predictive capacity of pulse pressure to estimate stroke volume, as assessed by bedside echocardiography in critically ill patients.

We hypothesize that pulse pressure will be able to adequately detect low values of stroke volume, and to track changes of stroke volume during commonly used dynamic cardiovascular interventions.

Pulse pressure transduced from an arterial line will be measured simultaneously with left ventricular outflow tract velocity time integral in a broad range of critically ill patients. Ancillary clinical, hemodynamic and echocardiographic data will also be registered.

详细描述

Critically ill patients often present complex cardiovascular derangements that impair oxygen delivery to the tissues leading to progressive organ dysfunction. Monitoring tissue perfusion and identifying the predominant hemodynamic patterns are key clinical objectives to implement resuscitative strategies and revert this vicious cycle. However, in different stages of acute circulatory dysfunction at the emergency department (ED) or the intensive care unit (ICU), or resource-limited settings, initial resuscitative decisions may be taken with basic clinical information only. In addition, many therapeutic interventions in the ICU such as fluids, diuretics, vasoactive drugs, and ventilatory-related maneuvers, among others, may jeopardize stroke volume (SV) in different ways, a fact that may evolve undetected due to the absence of specific hemodynamic monitors in all patients.

Unfortunately, there is no simple, costless, and universally available clinical monitor to detect low SV. There have been, however, physiological implications to use blood pressure components as a surrogate for SV. Although pulse pressure (PP) has been observed to be largely determined by SV in experimental conditions, the key issues remain to be clarified: can PP monitoring at the bedside be useful to detect extreme values, or track changes, in underlying SV? Moreover, what are the limitations, the contexts, the technical aspects, among other factors, that can affect this relationship, and thus help clinicians to potentially use PP as an early warning signal or a trigger for initial resuscitative or therapeutic interventions?

From a clinical point of view, the most relevant question is if PP monitoring can detect a low SV so that corrective measures might be implemented, while more advanced confirmatory monitoring, including point-of-care ultrasound, is pending. In addition, what are the potential confounders for this assumption? If these questions are answered, this simple and costless tool may be used as a first-line approach for macrohemodynamic profiling and clinical decision-making, which could be especially valuable in resource-limited settings and in sites where ultrasound or advanced cardiac output monitoring is not immediately available. In this multicenter, observational, cross-sectional study, we aim at answering the following research question:

Research Question

  • In critically ill patients, does pulse pressure, measured through an invasive arterial line, have an adequate predictive capacity to estimate stroke volume, as assessed by bedside echocardiography?
  • We hypothesize that pulse pressure will be able to adequately detect low values of stroke volume, and to track changes of stroke volume during commonly used dynamic cardiovascular interventions.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Admitted to ICU
  • Functioning arterial line in place

排除标准

  • Pregnancy
  • Inadequate arterial line transduction (see below)
  • Refusal of consent
  • Patient who requires extracorporeal circulation

结局指标

主要结局

Left ventricular outflow tract velocity time integral

时间窗: 1 day

measured by bedside echocardiography

Pulse pressure

时间窗: 1 day

measured from invasive arterial line

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (3)

Loading locations...