简要总结

M.M.A.TECH Ltd. product is an Acetabular Liner Family produced of an advanced polyimide - MP-1™.

M.M.A.TECH Ltd. produces the Liners according to EN ISO 13485:2012 approved manufacturing process and supplies them to the customer.

The aim of this study is to evaluate, in the frame of PMCF, the safety and performance of using AL-X MP1 Polyimide Acetabular liners in Total Hip Replacement surgery by clinical following up of patients for a period of 2 years .

详细描述

The procedure involves removal of the diseased parts of the joint, that is the damaged cartilage and adjacent bone, and replacing them with artificial parts which closely resemble in structure and/or function the removed native parts.

The artificial parts fit onto the reshaped bone and are fixed either with bone cement (e.g., polymethylmethacrylate) and press fit of the part(cemented), or by self-anchorage with bone ingrowth to its porous surface(cementless).

The design of the artificial parts may include a stem, a keel or pegs, which fit onto the medullary canal of the bone or into a hole pre-prepared in the bone. An artificial part may fit loosely and be fixed with bone cement, press-fit for self- anchorage or include extendible anchors which are retracted upon placement and extended thereafter so as to secure the implant in place.

Following fixation of the components, the joint is reduced and the soft tissue tension is appropriately checked to reassure stability of the joint.

The MP-1™ acetabular liner will be tapper locked in acetabular metal shells to resurface the acetabular socket in cementless total hip replacement.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
21 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • The inclusion criteria for subject participation in the study are:
  • (Patient must meet all of the following characteristics to be enrolled in the study):
  • Males and females, 21 to 90 years of age, inclusive;
  • Primary diagnosis of non-inflammatory arthritis (osteoarthritis) or inflammatory arthritis (rheumatoid arthritis), or patients requiring a revision as specified previously;
  • The patient or his/her legal guardian is willing to consent to participate in the study by signing and dating the approved consent form;
  • The patient will be available for follow-up through at least two years postoperative;
  • The patient has met an acceptable preoperative medical clearance and is free or treated for cardiac, pulmonary, hematological, etc., conditions that would pose excessive operative risk (FDA requirement);
  • The patient has a total Harris Hip Score of less than or equal to 60 (FDA requirement);
  • The patient meets none of the

排除标准

  • Exclusion Criteria:
  • with any of the following characteristics must be excluded from the study):
  • Patients known to have insufficient quantity or quality of bone support resulting from Conditions such as cancer, femoral osteotomy, Girdlestone resection, significant osteoporosis or metabolic disorders of calcified tissues. Patients with physical conditions tending to place extreme loads on implants such as morbid obesity (> 100 pounds over desirable body weight), Charcot joints, muscle deficiencies, or multiple joint disabilities;
  • Patients with active localized or systemic infection;
  • Patients who have not reached full skeletal maturity;
  • Patient has had a total knee arthroplasty of either leg
  • Patient psychological or neurological conditions which tend to preempt the patient's ability or willingness to restrict activities or follow medical advice, especially during the postoperative period, e.g.: drug or alcohol abuse, serious mental illness or retardation, or general neurological conditions;
  • The patient is participating in any other pharmaceutical, biologic or medical device clinical investigation;
  • Immunosuppressive disorders - immunosuppressive disorders are chronic conditions characterized by markedly inhibited ability to respond to antigenic stimuli. Examples of such conditions include patients who are on immunosuppressive therapy (corticosteroid hormones in large amounts, cytotoxic drugs, antilymphocytic serum or irradiation in large doses), patients receiving therapy to prevent homograft rejection, patients who have acquired immunodeficiency syndrome (AIDS), or auto-immune diseases (except rheumatoid arthritis).
  • Pregnancy.
  • Patients with known sensitivity to materials in the device.

研究组 & 干预措施

Polymer on Ceramic

Experimental

MP-1 Polymer on Ceramic articulation system

干预措施: MP-1 Polymer on Ceramic Articulation system (Device)

结局指标

主要结局

Clinical patient status according to Harris Score

时间窗: 6 months

\>60

Radiographic success

时间窗: 3 mth , 12mth, 24 mth post-surgery

o Radiographic success will be determined by femoral subsidence \< 2mm, acetabular migration \< 2mm, cup inclination \< 4°, no acetabular or femoral osteolysis, and acetabular and femoral lucencies less than 50% of visible porous coating

次要结局

未报告次要终点

研究者