跳至主要内容
临床试验/NCT05304026
NCT05304026Unknown不适用

Optimizing CO2 Injection Technique for Renal Artery Detection in Endovascular Abdominal Aortic Aneurysm Repair

University of Bologna1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2021年1月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
30
试验地点
1
主要终点
Aortic neck detection

研究概览

简要总结

Automated carbon dioxide (CO2) angiography is considered a safe diagnostic alternative to standard iodinated contrast medium (ICM) for endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA), especially in patients with preoperative renal function impairment.

Recent literature experiences describe the use of automated CO2 angiography in EVAR.

One of the main issues of CO2 angiography is the inability to detect the origin of the lowest renal artery (proximal neck visualization) that was estimated up to 38%.

In these experiences, the CO2 automated angiography is usually performed by a 5F pigtail catheter placed at renal arteries level.

The aim of the study is to evaluate the efficacy of a new automated CO2 injection technique by a 5F introducer (single hole catheter) positioned at the distal level of the proximal neck in detecting both renal arteries in the first diagnostic and completion angiographies.

详细描述

Endovascular aneurysm repair is currently a wide spread therapeutic option due to a lower 30-day morbidity/mortality compared with open repair (OR), especially in patients with high surgical risk. The routinary EVAR technique requires the use of iodinated contrast medium (ICM) which can cause contrast induced-acute kidney injure (CI-AKI). The incidence of CI-AKI after EVAR is estimated between 2% and 16% although renal insult can also be caused by microembolization, unplanned renal (or polar) artery coverage, renal artery lesion (as dissection) or post-operative inflammatory reaction.

In the past few years, several studies pointed out the importance of reducing the amount of iodinated contrast medium injected and proposed carbon dioxide (CO2) as an alternative to partially or completely replace ICM, especially in patients with preoperative chronic renal impairment.

According with the literature, manual or automatic CO2 injection provides a good quality imaging of both proximal and distal sealing zone in standard EVAR procedures and, combined with fusion imaging, allows to perform juxta and pararenal abdominal aortic aneurysm repair with fenestrated endograft reducing the total amount of ICM required to the procedure.

The most relevant limit to the use of CO2 is the inability to identify the proximal landing zone and the lowest renal artery that occurs in a significant number of cases (38.7%).

This limit could be related to the physical property of CO2 because, differently from ICM, it is a gas that does not completely fill the aortic lumen but it floats in the anterior portion of the aneurysmatic sac and does not allow the detection of renal arteries with a posterior origin.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with asymptomatic infrarenal abdominal aortic aneurysm admitted to the S. Orsola - Malpighi Hospital for a planned EVAR procedure. All patients underwent a preoperative computed tomography angiography (CTA) with a <2mm slices.

排除标准

  • Patients with contraindication for CO2 (cardiac septal defects, pulmonary arteriovenous malformations, pulmonary hypertension, severe emphysema)
  • Patients requiring advanced aortic repair (FEVAR, BEVAR)
  • Urgent cases

结局指标

主要结局

Aortic neck detection

时间窗: At the moment of CO2 injection during the procedure

Define the efficacy of the alternative CO2 injection technique in the detection of renal arteries in those cases when the usual technique doesn't succeed.

Procedure success

时间窗: At the moment of CO2 injection during the procedure

Define the efficacy of the alternative CO2 injection technique in the detection of renal arteries, hypogastric arteries and endoleaks at the final angiography in those cases when the usual technique doesn't succeed.

次要结局

  • Mortality(within 30 days from the procedure)
  • Adverse events(within 30 days from the procedure)
  • Rate of early reintervention(within 30 days from the procedure)
  • CO2 complications(within 30 days from the procedure)

研究者

发起方
University of Bologna
申办方类型
Other
责任方
Principal Investigator
主要研究者

Enrico Gallitto

Principal Investigator

University of Bologna

研究点 (1)

Loading locations...

相似试验

Optimizing CO2 Injection Technique for EVAR | 临床试验