REST/Collaborative Study Initiative With the Aim of Providing More Objective Information on Volume Status and Guiding Physicians in the Quest for DW
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 60
- 试验地点
- 1
- 主要终点
- Bioimpedance (BIA) appears to be useful for the achievement of DW. Resistance (R, measured in Ohm) is a basic property of BIA. Postdialytic weight (kg) is measured with a bed scale. R and DW will be reported in the outcome measure data tables
研究概览
简要总结
Background Very recently, a test aimed at assessing dry weight (DW) in hemodialysis (HD) patients has been developed, the "resistance stabilization test" (REST)
Aim of the study To verify if BIA-based DW (BIA DW) control is truly superior to current volume management in HD patients.
Protocol of the study DW determined with clinical methods (Clinical DW) is the gold standard by definition: Clinical DW is determined under strict clinical surveillance by the same attending physician. He will be helped by a clinical score of volume state about symptoms and signs of hypo- or hypervolemia. The physician is asked to adjust the DW of the candidates until their clinical score reaches zero before the BIA measurement. This Clinical DW will be compared with BIA DW, as obtained after performing REST
Phases of the study
The protocol study includes three sequential phases:
- the Clinical DW is the gold standard by definition. Items of form B must be strictly applied until score = 0 is achieved;
- The Clinical DW as indicated by the score = 0 becomes the target DW of the next standard HD session, in which BIA measurements are performed: R values are recorded continuously during the session.
- REST is performed the following dialysis session. As per protocol, these dialysis sessions may be one or more than one, until flattening of the curve of the ratio R0/Rt (R0 is R at time 0 and Rt is R at a given time t during the HD session) of less than + 1% over 20 minutes in the presence of ongoing UF, is obtained.
Primary outcome
The primary outcome is the definition for each patient of the gold standard DW when comparing the Clinical and the BIA DW. Two are the possible scenarios:
- the Clinical and the BIA DW will be very similar ( < + 0.5 kg). Therefore, a reciprocal validation of the two methods for that specific patient has been obtained;
- the Clinical and the BIA DW are different ( > + 0.5 kg). If the BIA DW will be confirmed in the following six dialysis sessions, it means that the gold standard DW for that patient is the BIA DW.
详细描述
Background Probing the dry weight (DW) was largely dependent on clinical subjective estimates until recently. New bedside non-invasive tools have been developed with the aim of providing more objective information on volume status and guiding physicians in the quest for DW. Among them, bioimpedance (BIA) appears to be very promising in the achievement of this goal. Resistance (R) and capacitance of tissues are the two basic properties in BIA. However, although impedance is an electrical property of tissues that can be directly used in body composition analysis, it is commonly embedded in predictive equations that are derived by correlation with criterion measures of body compartments.
Very recently, a test aimed at assessing DW in hemodialysis (HD) patients has been developed, the "resistance stabilization test" (REST). It is based on the following four items:
- one or more daily and/or alternate day HD sessions lasting 6 hours with ultrafiltration (UF) rate ≤ 0.5 kg/hour are planned;
- BIA measurements are determined injecting 800 microAmpere at 50 kilohertz alternating sinusoidal current with a standard tetrapolar technique (BIA 101 Impedance Analyzer). Resistance (R) is recorded starting at the beginning of the HD session (R0) and then, continuously, until the end of the 6-hour session;
- DW is defined as the weight achieved after flattening of the curve of the ratio R0/Rt (R0 is R at time 0 and Rt is R at a given time t during the HD session) of less than + 1% over 20 minutes in the presence of ongoing UF, indicating no further decline in extracellular volume;
- if at the end of the 6-hour HD session R stabilization is not attained, a new 6-hour HD treatment with UF rate ≤ 0.5 kg/h is planned until a BIA DW (according to the item 3) is obtained.
Aim of the study A study group is being created (REST/Collaborative Study Initiative) with the aim of verifying if BIA-based DW (BIA DW) control is truly superior to current volume management in HD patients.
Protocol of the study DW determined with clinical methods (Clinical DW) is the gold standard by definition: Clinical DW is determined under strict clinical surveillance by the same attending physician. He will be helped by a clinical score of volume state about symptoms and signs of hypo- or hypervolemia. The physician is asked to adjust the DW of the candidates until their clinical score reaches zero after a given number of HD sessions before the BIA measurement. This Clinical DW will be compared with BIA DW, as obtained after performing REST;
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •patients older than 18 years
- •maintenance HD three times weekly.
排除标准
- •dialysis vintage < 3 months
- •overt edema
- •liver cirrhosis
- •cardiac failure
- •serum albumin < 3 g/dl
- •metallic implants or a pacemaker
- •limb amputation.
结局指标
主要结局
Bioimpedance (BIA) appears to be useful for the achievement of DW. Resistance (R, measured in Ohm) is a basic property of BIA. Postdialytic weight (kg) is measured with a bed scale. R and DW will be reported in the outcome measure data tables
时间窗: up to 4 weeks
次要结局
未报告次要终点
研究者
Carlo Basile, M.D.
Scientific Director of the Division of Nephrology
Miulli General Hospital