跳至主要内容
临床试验/NCT02765295
NCT02765295Unknown不适用

Efficacy and Safety of Hydrogen Inhalation on Bronchiectasis (HYBRID): A Randomized, Multi-center, Double-blind, Parallel-group Study

Guangzhou Institute of Respiratory Disease5 个研究点 分布在 1 个国家目标入组 120 人开始时间: 2016年6月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
发起方
入组人数
120
试验地点
5
主要终点
Frequency of bronchiectasis exacerbations (BEs) within 12 months

研究概览

简要总结

This is a multi-center, randomized, double-blind, parallel-group trial. After a 2-week run-in period, eligible patients will be, based on the randomization codes kept in sealed envelopes, randomly assigned to receive usual care (mucolytics and/or chest physiotherapy) plus oxygen inahaltion (1 hr daily for 12 consecutive months) or hydrogen inhalation (1 hr daily for 12 consecutive months) provided by the sponsor. At 3 months after the end-of-treatment, a follow-up visit will be scheduled for all patients.

详细描述

This is a multi-center, randomized, double-blind, parallel-group trial. After 2-week run-in period, eligible patients will be, based on the randomization codes kept in sealed envelopes, randomly assigned to two groups.On the basis of usual care [ambroxool (30mg thrice daily), or N-acetylcysteine (0.2g thrice daily)/ serrapeptase (10mg thrice daily), or carbocisteine (500mg thrice daily) and/or chest physiotherapy (10 min, twice daily)], patients were randomized to receive either hydrogen (66.7%, 3L/min, 1 hr twice daily) inhalation or oxygen inhalation (3L/min, 1 hr twice daily) via nasal canula for 12 months. A follow-up visit at month 3 following end-of-treatment was also scheduled. The primary endpoint was the annual frequency of bronchiectasis exacerbations. Hospital visits were scheduled at baseline and months 1, 3, 6, 9, 12 and 15, respectively. At 3 months after the end-of-treatment, a follow-up visit will be scheduled for all patients.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Investigator)

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Out-patients of either gender, ex- or never-smokers, aged between 18 and 75 years
  • Clinically stable bronchiectasis, defined as respiratory symptoms and lung function parameters not exceeding normal daily variations and no acute upper respiratory tract infections for 4 consecutive weeks
  • Patients with a history of 2 or more bronchiectasis exacerbations (BEs) within the previous 2 years

排除标准

  • Other unstable concomitant systemic illnesses (i.e. coronary heart disease, recent cerebral stroke, severe uncontrolled hypertension, active gastric or duodenal ulcer, uncontrolled diabetes, malignancy, hepatic or renal dysfunction)
  • Concomitant asthma, allergic bronchopulmonary aspergillosis, or active tuberculosis
  • Concomitant chronic obstructive pulmonary disease as the predominant diagnosis
  • Treatment with inhaled, oral or systemic antibiotics within 4 weeks
  • Type 2 respiratory failure needing oxygen therapy or non-invasive mechanical ventilation
  • Females during lactation or pregnancy
  • Poor understanding or failure to properly operate the instrument
  • Participation in other clinical trials within 3 months.

研究组 & 干预措施

hydrogen inhalation

Active Comparator

The medical ultrasonic nebulizers with hydrogen/oxygen generating function (MUNHO) will be provided exclusively by the sponsor, Asclepius Meditec Inc (Shanghai, China). The MUNHO consists of a electrolytic tank which, by using direct current converted from alternating current (220 V), generates the hydrogen and oxygen gas from pure water (2:1 in volume). The MUNHO is also capable of nebulizing the water via ultrasounds with the hydrogen-oxygen mixture gas which is finally delivered to the patient's airways via the facial mask through a plastic tube. Typically, the volume of hydrogen-oxygen mixed gas is 3 liters per minute (3 L/min). Usual care referred to mucolytics (see below for details) alone or plus chest physiotherapy.

干预措施: medical ultrasonic hydrogen/oxygen nebulizer (MUNHO) (Device)

oxygen inhalation

Sham Comparator

Oxygen will be generated by an instrument provided by the sponsor, that would be capable of generating oxygen equivalent to that generated by the MUNHO (3L/min mixed gas containing 33.3% oxygen). Usual care referred to mucolytics [[ambroxool (30mg thrice daily), or N-acetylcysteine (0.2g thrice daily)/ serrapeptase (10mg thrice daily), or carbocisteine (500mg thrice daily)] alone or in combination with chest physiotherapy.

干预措施: Medical molecular mesh oxygen generator (Device)

结局指标

主要结局

Frequency of bronchiectasis exacerbations (BEs) within 12 months

时间窗: up to 12 months (1 year)

Frequency of bronchiectasis exacerbations (BEs) within 12 months

次要结局

  • Changes in sputum antioxidants levels (catalase, superoxide dismutase and total antioxidant capacity) at month 6 and 12 as compared with baseline(baseline, month 6 and month 12)
  • Changes in serum oxidant (hydrogen peroxide, reactive oxygen species) levels at month 6 and 12 as compared with baseline(baseline, month 6 and month 12)
  • Changes in serum antioxidants levels (catalase, superoxide dismutase and total antioxidant capacity) at month 6 and 12 as compared with baseline(baseline, month 6 and month 12)
  • Changes in CRP levels at month 6 and 12 as compared with baseline(baseline, month 6 and month 12)
  • Changes in sputum oxidant (hydrogen peroxide, reactive oxygen species) levels at month 6 and 12 as compared with baseline(baseline, month 6 and month 12)
  • Time to the first bronchiectasis exacerbations (BEs) within 12 months(up to 12 months)
  • Changes in spirometry, including FEV1, FEV1/FVC ratio and MMEF at each visit following randomization as compared with baseline(baseline, month 1, month 3, month 6, month 9 and month 12)
  • Changes in quality of life assessed by using Quality-of-Life Questionnaire--Bronchiectasis (QoL-B) at month 6 and 12 as compared with baseline(baseline, month 6 and month 12)

研究者

发起方
Guangzhou Institute of Respiratory Disease
申办方类型
Other
责任方
Principal Investigator
主要研究者

Weijie Guan

doctor

Guangzhou Institute of Respiratory Disease

研究点 (5)

Loading locations...

相似试验

Efficacy and Safety of Hydrogen Inhalation on... | 临床试验