跳至主要内容
临床试验/NCT06843135
NCT06843135尚未招募不适用

Synchrony in Cardiac Conduction: Assessing the Effects of Pacing on Cardiac Performance Through Magnetic Resonance Imaging and Advanced ECG-imaging

Amsterdam UMC, location VUmc0 个研究点目标入组 88 人开始时间: 2025年3月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
尚未招募
发起方
入组人数
88
主要终点
The primary endpoint is LV ejection fraction measured on CMR

研究概览

简要总结

Rationale Right ventricular pacing (RVP) is an established and effective therapy for patients with atrioventricular (AV) block. However, frequent RVP has been associated with left ventricular (LV) dyssynchrony and may progess heart failure. Conduction system pacing (CSP), a recently introduced alternative to RVP, aims to preserve physiological ventricular activation by engaging the heart's native conduction system. CSP includes diverse pacing approaches such as selective or non-selective His-bundle pacing, selective left bundle pacing, and LV-septal pacing, each with varying levels of fidelity in reproducing normal conduction. The mechanical impact of these distinct CSP strategies on left and right ventricular (RV) performance remains poorly understood.

Cardiac magnetic resonance imaging (CMR), a non-invasive and highly accurate tool for assessing cardiac structure and function, is uniquely positioned to elucidate the effects of CSP and RVP on cardiac performance. This trial aims to evaluate the comparative mechanical effects of these pacing strategies, potentially identifying the optimal approach for improving outcomes in patients with AV block.

Objective To investigate and compare the effects of CSP and RVP on cardiac performance, as assessed by CMR and electrocardiographic imaging (ECG-imaging).

Main Trial Endpoints The primary endpoints are measures of LV and RV performance assessed via CMR, including: ventricular volumes, ejection fraction (EF), and myocardial strain

Secondary Trial Endpoints

Secondary endpoints include:

Safety and Feasibility:

  • Adverse events (e.g., troponin release, lead displacement, arrhythmias, heart failure).
  • Technical feasibility (e.g., ease of device implantation, ability to maintain proper pacing).

Electrophysiological Assessment:

  • Degree of selectivity in engaging the native conduction system.
  • Ventricular activation times as assessed by ECG-imaging.

Trial Design This is a randomized, controlled, single blind, two-center crossover trial. Participants will undergo CSP and RVP in a randomized sequence, each for six months. CMR and ECG-imaging will be performed at 6 months (end of the first pacing phase) and 12 months (end of the second pacing phase).

Trial Population The trial will enroll 88 patients with a normal of at most mildly reduced ejection fraction and an indication for ventricular pacing.

Interventions Participants will undergo CMR and ECG-imaging at 6 months and 12 months.

Ethical Considerations This trial is designed to advance understanding of the mechanical and clinical effects of CSP relative to RVP in patients with AV block. The anticipated benefits include improved cardiac performance and enhanced quality of life. The primary burden to participants is the requirement for an additional CMR scan, which may be perceived as inconvenient or even stressful. The trial minimizes risk by utilizing established clinical procedures and closely monitoring participants for adverse events.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •In order to be eligible to participate in this study, a subject must meet all of the following criteria:
  • •Age ≥ 18 years
  • •Patients with a left ventricular ejection fraction of ≥35%
  • •Patients with an indication for ventricular pacing and high-degree atrioventricular block where the degree of anticipated RV pacing is >20% including:
  • •Third degree AV block
  • •Symptomatic or asymptomatic second-degree AV block
  • •High degree AV block
  • •Pace and ablate (AV-node ablation)

排除标准

  • •A potential subject who meets any of the following criteria will be excluded from participation in this study:
  • •CRT indication (patients with heart failure (NYHA >1) in sinus rhythm with left ventricular ejection fraction (LVEF) <35%, QRS duration >150 ms, and left bundle branch block (LBBB) QRS morphology despite optimised medical therapy)
  • •Inability to undergo CMR (i.e. severe claustrophobia or MRI contraindications)
  • •Life expectancy <12 months
  • •Indication for an implantable cardioverter defibrillator
  • •Presence of severe valve disease or mechanical valves
  • •Any prior attempt at implantation of an ICD, CRT, CSP
  • •Permanent AF with rapid ventricular response, unless pace and ablate

研究组 & 干预措施

Conduction system pacing

Active Comparator

干预措施: Ventricular pacing (Device)

Right ventricular pacing

Active Comparator

干预措施: Ventricular pacing (Device)

结局指标

主要结局

The primary endpoint is LV ejection fraction measured on CMR

时间窗: At 6 months after crossover

次要结局

未报告次要终点

研究者

发起方
Amsterdam UMC, location VUmc
申办方类型
Other
责任方
Principal Investigator
主要研究者

Luuk Hopman

Postdoctoral Research Fellow

Amsterdam UMC, location VUmc

相似试验

Synchrony in Cardiac Conduction: Assessing the... | 临床试验