跳至主要内容
临床试验/NCT02023476
NCT02023476已完成不适用

Nerve Function in Healthy Human Volunteers With Two Different Tourniquets

Medical University of Vienna2 个研究点 分布在 1 个国家目标入组 18 人开始时间: 2010年4月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
18
试验地点
2
主要终点
Nerve compression

研究概览

简要总结

Nerve injury is a serious potential complication associated with the clinical use of exsanguinating tourniquets in surgery. Recently, a novel narrow tourniquet has been proposed, with the claim that it may cause less compression of the nerves. We performed an in vivo comparison of a standard wide tourniquet with the new, narrow tourniquet. Our study specifically looked at neurologic markers in the upper extremity.

详细描述

The HemaClear ™ OHK Medical Device HemaClear™, approved by FDA, consists of a silicon ring wrapped in a stockinet sleeve and pull straps (Fig.1). It performs three functions - blood removal (exsanguinations), arterial flow occlusion, and placement of sterile stockinet 30. The ring is placed on the extremity and then straps are pulled proximally. The silicone ring rolls up the limb while the stockinet sleeve unfolds onto the limb. During the rolling up process, the ring exerts pressure and squeezes the blood away from the limb. Application of the device takes less than a minute.

The technique behind this device is fundamentally different from classic pneumatic tourniquets, as pressure is exercised by only a single silicon ring so that the profile is very small.

Zimmer A.T.S.®3000 The A.T.S.®3000 is an automatic broad tourniquet system with a Limb Occlusion Pressure (LOP) feature. It is the latest innovation in tourniquet technology and has FDA approval. It was invented by McEwen 4 and the basic function is described in several clinical trials and publications 28. The main difference to other pneumatic tourniquets is the LOP and the Recommended tissue pressure (RTP) feature. These parameters are suitable to optimize the pressure force on the tourniquet for each individual patient. The LOP is detected before inflating the tourniquet and the RTP is the LOP plus a safety margin to guarantee a blood free field (Operator & Service Manual Zimmer A.T.S.® 3000 Automatic tourniquet system REF 60-3000-101-00).

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
盲法
None

入排标准

年龄范围
18 Years 至 45 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • self defined Caucasian
  • clinically healthy
  • BMI of ≤ 30,
  • a systolic arterial blood pressure ≤190 mmHg,
  • no rash or dermatologic condition or tattoos which may interfere with the placement site
  • no neurovascular impairment.
  • all female participants received a pregnancy test at the initial screening visit.
  • Study population was restricted to Caucasians to enable an assessment of device caused redness or skin lesions, not possible in a mixed study population.

排除标准

  • 未提供

结局指标

主要结局

Nerve compression

时间窗: 20 Minutes

mg/mm2

次要结局

  • Nerve compression(20 minutes)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Dr. Florian M Kovar

Univ. Lektor Dr. med. univ

Medical University of Vienna

研究点 (2)

Loading locations...