The Effect of Selective Laser Trabeculoplasty (SLT) on Ocular Rigidity
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 150
- 试验地点
- 2
- 主要终点
- change in ocular rigidity
研究概览
简要总结
The purpose of this study is to examine the influence of selective laser trabeculoplasty (SLT) on ocular rigidity in glaucoma patients.
详细描述
Ocular Rigidity (corneal hysteresis and corneal resistance factor) is measured with the Ocular Response Analyzer (Reichert) before and 4 weeks after SLT (Q-switched 532 nm frequency doubled neodymium yttrium aluminium garnet laser with a spot size of 400 µm and a 3-ns pulse duration). The trabecular meshwork is treated with 100 spots over 360° and an energy of 0,8 mJ.
The purpose is to examine if selective laser trabeculoplasty changes ocular rigidity.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •glaucoma patients (primary open angle glaucoma, ocular hypertension) over the age of 18 who need further IOP reduction to control their glaucoma
排除标准
- •other forms of glaucoma (angle closure, secondary glaucoma, congenital, juvenile), acute psychosis, epilepsy
结局指标
主要结局
change in ocular rigidity
时间窗: 4 weeks
Is there a change in ocular rigidity (corneal hysteresis, corneal resistance factor) as measured with the Ocular Response Analyzer (Reichert) after selective laser trabeculoplasty?
次要结局
- IOP reduction(4 weeks)
研究者
Dr. Karin Pillunat
Principla Investigator
Technische Universität Dresden