跳至主要内容
临床试验/NCT05097612
NCT05097612已完成不适用

"Evaluation of a Soft Exoskeleton With Parallel Springs and Its Ability to Reduce Physical Load During Lifting and Leaning"

Swiss Federal Institute of Technology1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2021年11月8日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
30
试验地点
1
主要终点
Change in muscle activity of hip extensor muscles (placebo comparator - low support experimental intervention)

研究概览

简要总结

In this study the LiftSuit version 2.0 designed by Auxivo AG will be used. The LiftSuit is a soft wearable device that is designed to support workers perform physically demanding tasks including repetitive lifting and working in forward leaning positions. It is put on like a backpack and attached to the body using fabric bands and cuffs. Besides soft fabric parts the LiftSuit contains elastics elements. The elastic elements can be flexibly exchanged by the experimenter. For this experiment elastic elements of known stiffness will be hooked into the fabric frame.

详细描述

In a first step participants will try on the LiftSuit exoskeleton and adjust it to their body under supervision of the experimenter. When the LiftSuit exoskeleton is adjusted to the participant it is taken off to allow placement of sensors. The sensors used to record heart rate (Polar H9 heart rate monitor, Polar Electro Europe AG, Germany), muscle activity from 8 muscles in the back and hip region (Delsys Trigno, Delsys Europe, United Kingdom) and movement kinematics (OptiTrack motion capture system, NaturalPoint Inc., USA) will be placed by the experimenter (or participant him/herself). To verify that the electromyography sensors, are working and to obtain normalization values, participants will be instructed to conduct maximal voluntary contractions of each muscle that are being recorded. If needed single sensors can be replaced. After this the exoskeleton will be put back on.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Included will be volunteers of both sexes within working age (18 to 65 years).

排除标准

  • •Participants will be excluded if they cannot perform the tasks (squat lifting and forward leaning) due to physical limitations. Furthermore, people who report acute joint or muscle pain or stiffness, or a self-reported history of such problems will be excluded.

研究组 & 干预措施

Healthy participant

Experimental

This is a repeated measures design. All participants receive both the intervention and the placebo comparator.

干预措施: Placebo LiftSuit Exoskeleton (Device)

Healthy participant

Experimental

This is a repeated measures design. All participants receive both the intervention and the placebo comparator.

干预措施: LiftSuit Exoskeleton (low support level) (Device)

Healthy participant

Experimental

This is a repeated measures design. All participants receive both the intervention and the placebo comparator.

干预措施: LiftSuit Exoskeleton (medium support level) (Device)

Healthy participant

Experimental

This is a repeated measures design. All participants receive both the intervention and the placebo comparator.

干预措施: LiftSuit Exoskeleton (high support level) (Device)

结局指标

主要结局

Change in muscle activity of hip extensor muscles (placebo comparator - low support experimental intervention)

时间窗: 2 hours

An elastic band placed external to the body parallel to the spine and over the hip joint is likely to support the muscles that extend the hip and back. Less hip extensor muscle (m. gluteus maximus, hamstrings) activity is expected in LiftSuit conditions compared to the placebo comparator condition.

Change in muscle activity of back extensor muscles (placebo comparator - low support experimental intervention)

时间窗: 2 hours

An elastic band placed external to the body paralell to the spine and over the hip joint is likely to support the muscles that extend the hip and back. Less back muscle activity (erector spinae at lumbar and thoracic level) is expected in LiftSuit conditions compared to the placebo comparator condition.

次要结局

  • Change in muscle activity of hip extensor muscles related to stiffness level of the Elastic Energy Storages (low, medium, high stiffness).(2 hours)
  • Change in muscle activity of back muscles related to stiffness level of the Elastic Energy Storages (low, medium, high stiffness).(2 hours)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验