JPRN-UMIN000041310已完成未知
Development of a new device for improving accuracy and feasibility in neuromuscular monitoring with acceleromyography: a prospective randomized trial - Development of a new device for improving accuracy and feasibility in neuromuscular monitoring with acceleromyography: a prospective randomized trial
Korea University Guro Hospital, Korea University College of Medicine, Seoul, Republic of Korea0 个研究点目标入组 57 人开始时间: 2020年10月1日最近更新:
适应症
试验速览
- 阶段
- 未知
- 状态
- 已完成
- 发起方
- 入组人数
- 57
研究概览
简要总结
The agreement between AMG and EMG in each group was assessed using the Bland Altman method. In group B, the repeatability coefficient of T1 was significantly lower during the recovery to T1 of 25% and TOF ratio of 0.9 (P????0.017 and 0.033, respectively), indicating higher precision. The mean differences of bias between AMG and EMG in TOF ratio of 0.9 were 6.839 in group NB and 3.922 in group B. The wide limits of agreement in group NB was slightly narrowed in group B but without significance.
研究设计
- 研究类型
- Interventional
入排标准
- 年龄范围
- 18years-old 至 75years-old(—)
- 性别
- All
入选标准
- 未提供
排除标准
- •Patients were excluded if they had a known hypersensitivity to the drugs used in this study, known neuromuscular disease, significant hepatic or renal dysfunction, cerebrovascular disease, or a body mass index >30.0 kg m-2. Patients with hemodynamic instability with an increase or decrease in blood pressure of 30% or more of the baseline over 15 minutes during surgery, and blood loss of 1L or more during surgery.
研究者
相似试验
已完成
不适用
Development of MMG/EMG Transducer for Evaluation of Skeletal Muscle ContractioHealthy subjectJPRN-UMIN000025814Okayama University10
已完成
不适用
Method To Measure Protein Digestion & AbsorptionPulmonary Disorder, Chronic ObstructiveChronic Heart FailureNCT02065141Texas A&M University74
已完成
不适用
Evaluation of a Novel Medical Device to Facilitate Gel Instillation During Change of Long-term Urinary CathetersUrinary CathetersRetention, UrinaryIncontinence, UrinaryAnesthesia, LocalNCT03289117Region Skane32
暂停
不适用
Changes in Electromyographic Activity in Aligner Treatment of Adult Patients With and Without Nocturnal BruxismSleep BruxismMasseter Muscle HypertrophyGrinding TeethNCT06343194Fondazione Policlinico Universitario Agostino Gemelli IRCCS22
招募中
不适用
Use of Accelerometer for Quantification of Neurogenic Orthostatic Hypotension SymptomsAutonomic FailurePure Autonomic FailureHypotension, Neurogenic OrthostaticMultiple System AtrophyHypotension, Parkinsonism OrthostaticNCT04782830Vanderbilt University Medical Center29