跳至主要内容
临床试验/NCT00752713
NCT00752713已完成不适用

Strain-Encoded Magnetic Resonance Imaging for Evaluation of Left Ventricular Function and Acute Myocardial Infarction

RWTH Aachen University1 个研究点 分布在 1 个国家目标入组 48 人开始时间: 2007年1月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
48
试验地点
1
主要终点
Left ventricular function

研究概览

简要总结

The aim of the study was therefore to evaluate whether myocardial deformation imaging performed by SENC allows for quantification of regional left ventricular function and is related to transmurality states of infarcted tissue in patients with acute myocardial infarction (AMI).

详细描述

CMR was performed in 38 consecutive patients with AMI 3±1 days after successful reperfusion using a clinical 1.5 Tesla MR-scanner. Ten healthy volunteers served as controls. SENC is a technique that directly measures peak circumferential strain from long-axis views and peak longitudinal strain from short axis views. Measurements were obtained for each segment in a modified 17 segment model. Wall motion and infarcted tissue were evaluated semi-quantitatively from SSFP cine sequences and contrast-enhanced-MR-images and were then related to myocardial strain. Comparison of peak circumferential strain assessed by SENC and MR-tagging was performed.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
30 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with AMI after successful reperfusion
  • Healthy volunteers in control group

排除标准

  • No reperfusion

结局指标

主要结局

Left ventricular function

时间窗: 01.01.2007 until 01.02.2007

次要结局

  • Transmurality(01.01.2007 until 01.02.2007)

研究者

申办方类型
Other

研究点 (1)

Loading locations...