IntraOperative UltraSound Guided Versus Wire Guided Versus Magnetic Seed Guided Breast-conserving Surgery for Non-palpable Tumors.The MANOLA Study Multi-center, Randomized, Open-label Clinical Trial
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 1,302
- 试验地点
- 5
- 主要终点
- Involved resection margins.
研究概览
简要总结
This is a multi-center, randomized, open-label clinical trial that will enroll 1302 adult patients with non-palpable breast lesions. Participant eligible for the study will be randomized in a 1:1:1 ratio to one of the pre-surgery lesion localization: IOUS HydroMark™ (experimental arm A), magnetic Sirius Pintuition Seed® (experimental arm B) and the wire localization technique (control arm). The randomization will be stratified by lesion type (solid non-palpable (type B); non-solid non-palpable (e.g., microcalcification clusters, architectural distortive areas) (type C); post-NACT residual lesions (type D), and clinical center.
详细描述
Breast-conserving surgery is the gold standard treatment for early breast cancer, since it has shown disease-free survival rates equivalent to those of mastectomy, offering the advantages of cosmetic outcome preservation, a better quality of life and a decrease in psychological morbidities. These important aspects, along with the general goal of reducing the extent of surgical excisions, have increased the need for an effective pre- surgery lesion localization and surgical guidance techniques. Reported rates of margin involvement after BCS range from 10 to over 40%, and positive resection margin is one of the strongest predictive factors for local recurrence. This event requires additional surgical procedures (re-excision or mastectomy) and/or radiotherapy boost, leading to higher healthcare costs and worse cosmetic outcomes, in addition to further stress for surgeons and patients.
Wire localization (WL) is the most used method for non-palpable breast lesions, with clear margins reported in a range of 70.8%-87.4% of cases. Recognized advantages of wires are the widespread availability and the moderate price. Moreover, wires emit no ionizing radiation and can be stored safely. Although WL is highly effective, with approximately 2.5% of unsuccessful wire localizations associated with multiple lesions, small lesions, lesions containing extensive microcalcifications and small surgical specimens, it still yields several disadvantages. The procedure is unpleasant and causes patient discomfort; wire migration within the breast, and more infrequently outside the breast, has also been reported. The hookwire can be transected during the surgery, with pieces being retained in the breast post- operatively. Finally, this localization approach requires adequate coordination between trained breast radiologists and surgeons because the wire placement has to occur on the day of surgery to avoid displacement. This limitation can lead to inconvenience and delay in the operating room or suboptimal localization. Moreover, wire localization could limit the surgical approach and cause a potential worse cosmetic outcome; the placement route of the wire, chosen by the radiologist, often dictates incision choice for the surgeon who then has to follow the wire's course during dissection.
Magnetic seed is a relatively new localization technology for non-palpable breast lesions. The localization system includes a magnetic seed, that may be positioned using a needle under radiological guidance days, weeks or months before the surgical procedure and it offers a demonstrated reduced risk of migration compared to wire-guided localization. This method has no radiation emission, so that the signal does not decay over time, and it does not require a destruction protocol in comparison to radioactive seeds. Literature describes magnetic guidance as safe and feasible. The magnetic seeds may be seen on breast imaging including ultrasound, mammography, and tomosynthesis. MRI is not contraindicated although a degree of movement artifact would be expected as with any metal clip. The magnetic device has the potential of localizing lesions accurately, and may reduce re- excision rates, pain and excision specimen weight. The main disadvantages of magnetic seed are the high costs of devices and the creation of MRI artefacts. Nevertheless, magnetic seed localization still seems to be one of the most promising recent technological innovation in BCS. The Sirius Pintuition Seed® is a permanent magnetic seed that accurately marks the tumor and helps the procedure of surgical removal from any direction. The magnetic seed is robust and is encapsulated in high-grade, nickle-free biocompatible titanium. Sirius Pintuition is a wire-free localization technology designed to provide navigational guidance through a dedicated software that offers directional guidance using audio and visual feedback.
All the traditional breast localization techniques may be described as essentially blind, since they do not allow the direct visualization of breast lesions during surgery. In 1988 Rifkin et al. firstly described ultrasound (US) as a tool for localizing breast masses during surgery and facilitating their surgical excision. Many other successful experiences followed, for palpable and non-palpable BC and even for post neoadjuvant residual lesions. A recently published prospective study demonstrated the efficacy of IOUS for all the types of BC lesions. Nevertheless, systematic US performance during BCS is still regarded as a new developing concept, being underused in this surgical oncology field. Intra-operative ultrasound-guided surgery (IOUS) is the only technique allowing a real-time visualization of BC and resection margins running control during all surgical phases. Previous series reported glaring advantages over the other techniques both for oncological and cosmetic outcomes.
HydroMarkTM clip has the potential to amplify the efficacy of IOUS, since the clip is easy to view, and it allows an easier guide in every phase of surgery. The HydroMarkTM marker hydrogel hydrates to provide up to 12 months of ultrasound visibility and it offers permanent stereotactic, tomosynthesis, and X-ray visibility. Moreover, it does not contraindicate Magnetic Resonance Imaging (MRI). It is demonstrated that the clip offers a permanent MRI visibility without generating any artefact, while it results uniquely distinguishable on a T2 sequence for up to 12 months. The results of a recently published study described the procedure of localization the clip under ultrasound as a faster and more comfortable procedure for the patient compared to the wire localization. HydroMark clip costs are slightly higher than a stadard stereotactic clip. The use of IOUS with HydroMark clips have the potential to improve patients' experience, with a particular attention in preserving the cosmetic aspect, leading to an improved quality of life in this specific population. According to the available scientific evidences IOUS technique allows excellent oncological and cosmetic outcomes and contribute to organizational aspects improvement in breast-conserving surgery compared with the traditional methods of wire-guide surgery. Moreover, it seems to be cost-saving with respect to magnetic seeds techniques, without limiting the possibility of further MRI evaluations of the patients.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •Patients with non-palpable breast cancer candidate for breast-conserving surgery;
- •Female patients;
- •Patients aged ≥ 18 years;
- •Patients with histologic diagnosis of cT1-T2 invasive BC or ductal carcinoma in situ;
- •Patients amenable for BCS after neoadjuvant chemotherapy;
- •Patients who are able to give informed consent.
排除标准
- •Pregnancy or lactation;
- •Patients with locally advanced disease or metastatic disease;
- •Patients with palpable breast carcinoma;
- •Patients candidate for mastectomy;
- •Patients who are unable to give informed consent
- •Patients candidate for mastectomy.
研究组 & 干预措施
IntraOperative Ultrasound (IOUS) HydroMark™
It is an advanced localization technique for non-palpable breast lesions, leveraging real-time ultrasound guidance combined with an ultrasound-visible tissue marker (HydroMark™) to facilitate precise tumor resection during breast-conserving surgery (BCS).
干预措施: IOUS HydroMark™ (Procedure)
Magnetic Sirius Pintuition Seed®
It is an advanced, wire-free localization system designed for precise surgical guidance in non-palpable breast lesions. This technology utilizes a small, permanent magnetic seed that can be implanted into the tumor days, weeks, or even months before surgery, offering greater flexibility compared to traditional wire localization.
干预措施: Magnetic Sirius Pintuition Seed® (Procedure)
Wire localization
It is the most widely used preoperative technique for guiding the surgical removal of non-palpable breast lesions. This method involves the insertion of a thin hooked wire into the lesion under radiological guidance (ultrasound, mammography, or stereotactic guidance) on the day of surgery. The wire serves as a physical guide for the surgeon, ensuring precise excision of the target lesion.
干预措施: Wire localization (WL) (Procedure)
结局指标
主要结局
Involved resection margins.
时间窗: Through study completion, an average of 2 years
Compare the efficacy of the IOUS HydroMark™ and magnetic Sirius Pintuition Seed® versus the wire localization technique in terms of involved resection margins. Positive margin rate, defined as the number of patients with ink on invasive cancer or ductal carcinoma in situ with a resection margin \< 2mm out of the total number of enrolled patients.
次要结局
- Postoperative complications(Through study completion, an average of 2 years)
- Re-excision rate(Through study completion, an average of 2 years)
- Target lesion removal rates(Through study completion, an average of 2 years)
- Closest margin width(Through study completion, an average of 2 years)
- Calculated resection ratio (CRR)(Through study completion, an average of 2 years)
- Tumor and surgical specimen volume ratio(Through study completion, an average of 2 years)
- BREAST-Q score(Through study completion, an average of 2 years)
- Resource consumption and estimation of costs(Through study completion, an average of 2 years)
- Number of re-excisions within the first 6 months following the first surgery(Through study completion, an average of 2 years)
- EQ-5D-5L(Through study completion, an average of 2 years)