简要总结
The investigators propose a single-center multiple crossover randomized trial to determine the efficacy of four warming devices and five warming blankets. The investigators will measure cutaneous heat loss/ gain using thermal flux transducers in unanesthetized volunteers.
详细描述
The investigators propose a single-center, assessor-Blinded, multiple crossover randomized trial to determine the efficacy of four warming devices and five blankets. The investigators will measure cutaneous heat loss/ gain using thermal flux transducers in unanesthetized volunteers.
American Society of Anesthesiologists (ASA) physical status 1 and 2 adults with body-mass index 20-33 kg/m2 will be included in this study. Volunteers will be excluded if they have serious skin lesions, history of allergy or skin sensitivity to tape or adhesive materials, serious vascular disease in the arms including Raynaud's Syndrome, or a history of recent fever or infection.
20 volunteers will be randomized to one of 5 different sequence groups: 1. Mistral Air, Blower MA1200-PM. plus the Adult Blanket plus, MA2220, 2. Mistral Air, Blower MA1200-PM plus the Premium Adult Blanket, 3320, 3. 3M, Bair Hugger, Blower 775 plus Blanket full body, 30000, 4. Smiths Medical, Blower L1-CW-100V, plus Blanket full body SWU-2001, 5. Care Essential, Cocoon, Blower CWS5000 plus Blanket Full Body blanket (CLM0101).
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Body-mass index 20-33 kg/m2
- •Age 18-40 yrs.
- •ASA Physical Status 1-2.
排除标准
- •Serious skin lesions
- •History of allergy or skin sensitivity to tape or adhesive materials
- •History of serious vascular disease in the arms, including Raynaud's Syndrome
- •History of recent fever or infection
研究组 & 干预措施
ABCDE
A. Volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. B. After a 40 minutes washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. Finally and after a last 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes.
干预措施: Adult blanket plus, MA2220 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
ABCDE
A. Volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. B. After a 40 minutes washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. Finally and after a last 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes.
干预措施: Premium adult blanket, 3320 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
ABCDE
A. Volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. B. After a 40 minutes washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. Finally and after a last 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes.
干预措施: Blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 (Device)
ABCDE
A. Volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. B. After a 40 minutes washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. Finally and after a last 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes.
干预措施: FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system. (Device)
ABCDE
A. Volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. B. After a 40 minutes washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. Finally and after a last 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes.
干预措施: Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system (Device)
BDECA
B. Volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. C. After a 40-minute washout period, the volunteer will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. Finally and after a last 40-minute washout period, the volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: Adult blanket plus, MA2220 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
BDECA
B. Volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. C. After a 40-minute washout period, the volunteer will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. Finally and after a last 40-minute washout period, the volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system. (Device)
BDECA
B. Volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. C. After a 40-minute washout period, the volunteer will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. Finally and after a last 40-minute washout period, the volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: Premium adult blanket, 3320 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
BDECA
B. Volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. C. After a 40-minute washout period, the volunteer will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. Finally and after a last 40-minute washout period, the volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: Blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 (Device)
BDECA
B. Volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. C. After a 40-minute washout period, the volunteer will be covered with the Blanket full body, 30000 connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. Finally and after a last 40-minute washout period, the volunteers will be covered with the Adult Blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system (Device)
CEBAD
C. Volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. After a 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. Finally and after a last 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes.
干预措施: Adult blanket plus, MA2220 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
CEBAD
C. Volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. After a 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. Finally and after a last 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes.
干预措施: Premium adult blanket, 3320 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
CEBAD
C. Volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. After a 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. Finally and after a last 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes.
干预措施: Blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 (Device)
CEBAD
C. Volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. After a 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. Finally and after a last 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes.
干预措施: FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system. (Device)
CEBAD
C. Volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. After a 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. Finally and after a last 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes.
干预措施: Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system (Device)
DCAEB
D. Volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: Adult blanket plus, MA2220 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
DCAEB
D. Volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: Premium adult blanket, 3320 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
DCAEB
D. Volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: Blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 (Device)
DCAEB
D. Volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system. (Device)
DCAEB
D. Volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. C. After a 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. E. After a 40-minute washout period, the volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes.
干预措施: Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system (Device)
EADBC
E. Volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. Finally and after a last 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes.
干预措施: Adult blanket plus, MA2220 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
EADBC
E. Volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. Finally and after a last 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes.
干预措施: Premium adult blanket, 3320 blanket connected to the Mistral Air, Blower MA1200-PM system. (Device)
EADBC
E. Volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. Finally and after a last 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes.
干预措施: Blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 (Device)
EADBC
E. Volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. Finally and after a last 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes.
干预措施: FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system. (Device)
EADBC
E. Volunteers will be covered with the blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system for 30 minutes. A. After a 40-minute washout period, the volunteers will be covered with the adult blanket plus, MA2220 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. D. After a 40-minute washout period, the volunteers will be covered with the FilteredFlo® Air Blanket connected to the WarmAir® Convective Warming system for 30 minutes. B. Finally and after a last 40-minute washout period, the volunteers will be covered with the Premium Adult Blanket, 3320 connected to the Mistral Air, Blower MA1200-PM system for 30 minutes. C. Finally and after a last 40-minute washout period, the volunteers will be covered with the blanket full body, 30000 blanket connected to the 3M, Bair Hugger, Blower 775 for 30 minutes.
干预措施: Blanket Full Body blanket (CLM0101) connected to the Care Essential, Cocoon, Blower CWS5000 system (Device)
结局指标
主要结局
Heat transfer, thermal flux
时间窗: 30 minutes
While using one of the 5 different warming blanket and warming blower systems, heat transfer will be measured on at 15 sites: Head, upper arm, forearm, hand, finger, back, chest, abdomen, medial thigh, lateral thigh, posterior thigh, anterior calve, posterior calves, foot and toe.
次要结局
- Thermal comfort(30 minutes)