跳至主要内容
临床试验/NCT04854239
NCT04854239已完成4 期

Accuracy of Half-guided Implant Placement With Machine-driven or Manual Insertion: a Prospective, Randomized Clinical Study

Semmelweis University2 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2017年1月1日最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
入组人数
40
试验地点
2
主要终点
Global apical implant position deviation

研究概览

简要总结

The aim of the present prospective randomized controlled study is to compare the accuracy of implant placement performed either with a surgical motor or a torque wrench as part of a half-guided surgical protocol after maxillary sinus floor augmentation.

详细描述

Implant insertion with half-guided surgical protocol was utilized by surgical motor (machine-driven group) or torque wrench (manual group) in the maxilla. Forty patients were randomly divided in two study groups; 20 implants were inserted with a surgical motor and 20 implants with a torque wrench. After the healing period, accuracy comparison method between planned and actual implant positions was performed based on digital intraoral scan. Coronal, apical and angular deviation parameters, insertion time and maximum insertion torque was evaluated.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

盲法说明

Patients were not aware whether implant were placed with a contra-angled handpiece or with a torque wrench. 3D implant position accuracy evaluation was performed blinded, randomization sequence was revealed after analysis.

入排标准

年龄范围
29 Years 至 67 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • at least one edentulous maxillary premolar or molar site treated successfully by sinus floor elevation with a xenogenic bone substitute (cerabone, botiss biomaterials, Zossen, Germany) confirmed by preoperative cone-beam computed tomography
  • full- mouth plaque and bleeding scores (FMPS and FMBS) <20%
  • good patient compliance (including willingness to participate in the follow-up procedures)
  • signed informed consent

排除标准

  • clinically relevant diseases (e.g.: diabetes, rheumatism, cancer)
  • systemic steroid or bisphosphonate use
  • acute or chronic inflammatory processes

结局指标

主要结局

Global apical implant position deviation

时间窗: 3 months after implant placement

Measurement: comparison of planned and actual implant position in a virtual model. Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA). Unit: mm

Horizontal coronal implant position deviation

时间窗: 3 months after implant placement

Measurement: comparison of planned and actual implant position in a virtual model. Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA). Unit: mm

Global coronal implant position deviation

时间窗: 3 months after implant placement

Measurement: comparison of planned and actual implant position in a virtual model. Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA). Unit: mm

Horizontal apical implant position deviation

时间窗: 3 months after implant placement

Measurement: comparison of planned and actual implant position in a virtual model. Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA). Unit: mm

Angular implant position deviation

时间窗: 3 months after implant placement

Measurement: comparison of planned and actual implant position in a virtual model. Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA). Unit: mm

次要结局

  • Duration of implant insertion(During implant insertion)
  • Implant insertion torque(During implant insertion)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Balint Molnar

Dr. Balint Molnar DMD, PhD, associate professor

Semmelweis University

研究点 (2)

Loading locations...

相似试验