Effects of Transcutaneous Electrical Nerve Stimulation on Sympathetic and Parasympathetic Nervous System in Patients With Hypertension: a Randomized Clinical Trial

Federal University of Health Science of Porto Alegre2 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2014年8月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
发起方
入组人数
60
试验地点
2
主要终点
Heart Rate Variability

研究概览

简要总结

Hypertension has high prevalence and poor control rates and is considered one of the major modifiable risk factors for cardiovascular system diseases, and one of the most important public health problems. The imbalance of the autonomic cardiovascular control, which can be considered as a major etiologic factor in the development of essential hypertension is characterized by increased sympathetic activity and reduced parasympathetic activity possible.

Cardiovascular disease is the leading cause of death and disability in the world and autonomic imbalance is associated with several pathological conditions, and may be a final common pathway for the increased morbidity and mortality of cardiovascular diseases. In this sense, the heart rate variability (HRV) is a quantitative marker of sympathetic and parasympathetic activity, which can be used to assess disease and mortality as a noninvasive technique.

TENS is a noninvasive therapeutic modality, easy to handle, it has no side effects or interactions with medications being used for the relief of pain by sensory stimulation through peripheral nerves and mainly for control and treatment of acute and chronic pain . Research on the effect of TENS on the sympathetic and parasympathetic nervous system activity remain controversial, especially regarding the parameters to use.

The aim of this study is to investigate the effects of TENS on the sympathetic and parasympathetic nervous system in patients with hypertension by heart rate variability and blood pressure variability.

This is a randomized clinical trial, double blind, where hypertensive patients were randomized to three groups: high-frequency TENS (100 Hz) n = 20, low frequency TENS (4 Hz) n = 20 and n = 20 placebo. Evaluations will be made in a single session. The results will be assessed by a blinded investigator and randomization will be done electronically.

It is expected to evaluate how often TENS exerts more influence in the modulation of sympathetic and parasympathetic system.

详细描述

Data collection was performed at the Laboratory of Clinical Investigation (LIC) Institute of Cardiology. Initially, patients rested for 30 minutes, and during this period has been completed the evaluation form with the identification data and questions about the patient's clinical status, such as checking blood pressure, weight and height.

Patients were randomized to group of high frequency (100 Hz / 200μs), low frequency (4 Hz / 200μs) or placebo. The placebo group received an active current for 30 seconds, and then gradually decreased for 15 seconds to not pass any current. This approach aims at masking the investigator and subject (RAKEL et al., 2010). Eligible subjects were randomly assigned in blocks, by electronic randomization (www.randomization.com).

The adhesive electrodes were used, size 9x5 cm, placed in bilateral paravertebral region of the T1 segment of the thoracic spine at L2 lumbar spine. Before the application of TENS (IBRAMED®), the skin was cleaned in place of the current application with alcohol to avoid any barrier conduction of electrical current.

The sessions took place at the same time of the day, throughout the protocol, the participants were comfortably accommodated in an acclimatized room (23ºC) in a supine position, head elevation of 30º with knees resting on a wedge. All the participants were forbidden to perform exhaustive exercises and intake caffeine at least two hours before the intervention and instructed to have a meal before the assessment.

TENS was applied for thirty minutes, with the frequency defined according to randomization. The intensity of the current was delivered at sensory-level intensity, adjusted every 5 minutes by the sensory threshold, during the 30 minutes as tolerated by each subject, but without motor contraction or pain reported by the subject.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Previous Hypertension diagnosis, systolic blood pressure (SBP) > 140 mm Hg and/or diastolic blood pressure (DBP) >90 mm Hg and clinical stability with no change in medications for at least 2 months preceding the study.

排除标准

  • Presence of any comorbidity such as diabetes; congestive heart failure; unstable angina; myocardial infarction; acute inflammation; peripheral vascular disease; associated neurological disease; acute respiratory illness; infectious disease or fever; cardiac pacemaker; unstable ventricular arrhythmia; active smokers; obesity; musculoskeletal disease in the lower limbs; changes in the electrocardiogram; smoker; treatment with beta blockers, steroids, hormones or chemotherapy or change in drug therapy were excluded from the study.

研究组 & 干预措施

TENS High Frequency 100 Hz

Experimental

TENS was applied for thirty minutes, with the frequency defined according to randomization. The intensity of the current was delivered at sensory-level intensity, adjusted every 5 minutes by the sensory threshold, during the 30 minutes as tolerated by each subject, but without motor contraction or pain reported by the subject.

干预措施: TENS High Frequency (Device)

TENS Low Frequency 4 Hz

Active Comparator

TENS was applied for thirty minutes, with the frequency defined according to randomization. The intensity of the current was delivered at sensory-level intensity, adjusted every 5 minutes by the sensory threshold, during the 30 minutes as tolerated by each subject, but without motor contraction or pain reported by the subject.

干预措施: TENS Low Frequency (Device)

TENS Placebo

Placebo Comparator

The placebo group received an active current for 30 seconds, and then gradually decreased for 15 seconds to not pass any current. This approach aims at masking the investigator and subject (RAKEL et al., 2010).

干预措施: TENS Placebo (Device)

结局指标

主要结局

Heart Rate Variability

时间窗: 2 Hours

For the analysis of heart rate variability (HRV), the time of RR intervals obtained from continuous ECG signal recorded by Finapres device (Ohmeda 2300, Colorado, USA) series. The time series of RR will be analyzed in the time and frequency and variability parameters and autonomic balance will be obtained. In the time domain we calculate the mean values of RR intervals, standard deviation and the square root of the sum of the square of successive differences (rMSSD). The acquisition of electrocardiogram signal (ECG) was performed immediately before and after the interventions for a 10-minute period, with the subject at rest.

次要结局

未报告次要终点

研究者

发起方
Federal University of Health Science of Porto Alegre
申办方类型
Other
责任方
Principal Investigator
主要研究者

Rodrigo Della Méa Plentz

Effects of transcutaneous electrical nerve stimulation on sympathetic and parasympathetic nervous system in patients with hypertension: a randomized clinical trial

Federal University of Health Science of Porto Alegre

研究点 (2)

Loading locations...

相似试验

Transcutaneous Electrical Nerve Stimulation on... | 临床试验