Development of a Prostate Deformation Model to Enable Accurate Registration of Endorectal Coil Magnetic Resonance Images (ERC-MRI) to Reference Treatment Planning CT Images

University Health Network, Toronto2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2005年2月最近更新:
适应症

试验速览

阶段
2 期
状态
已完成
入组人数
20
试验地点
2
主要终点
The primary aim of this study is to develop a prostate deformation model using the finite element method from anatomic MR images of the prostate gland acquired with and without ERC.

研究概览

简要总结

When we acquired MR images of the prostate gland using a coil (receiver antenna) inside the rectum, we can see areas with tumour in the prostate gland, and well as details of the anatomy. The coil inside the rectum changes the shape of the prostate gland. In order to use this images to help target radiation therapy to the tumour better, we need to deform the images to the original shape of the prostate gland without the coil. In this study, we will develop a way to deform the images accurately.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Male
接受健康志愿者

入选标准

  • adenocarcinoma of the prostate
  • patient undergoing dose escalated conformal EBRT
  • low or intermediate risk prognostic factors: PSA < or equa to20, gleason score <8, T <T3, N category 0 or X, M category 0 or X
  • > or equal to 18 years of age
  • ECOG performance status 0 or 1

排除标准

  • contraindications to MRI
  • bleeding diathesis and anti-coagulative therapy that cannot be temporarily ceased precluding insertion of fiducial markers
  • IFB or collagen vascular disease
  • previous colorectal surgery
  • previous pelvic RT

结局指标

主要结局

The primary aim of this study is to develop a prostate deformation model using the finite element method from anatomic MR images of the prostate gland acquired with and without ERC.

次要结局

未报告次要终点