跳至主要内容
临床试验/NCT04765397
NCT04765397已完成不适用

The Effect of Bipolar and Monopolar Resectoscope Use on Optic Nerve Diameter in Transurethral Resection Procedures Under Spinal Anesthesia

Bursa Yüksek İhtisas Education and Research Hospital2 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2018年7月20日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
80
试验地点
2
主要终点
optic nerve sheath diameter(mm)

研究概览

简要总结

In this study, in patients with benign prostatic hypertrophy, monopolar and transurethral prostate using bipolar techniques in resection; serum electrolytes in the perioperative period, osmolarity can occur in hemodynamic parameters the effect of changes on optic nerve diameter by ultrasonography.

详细描述

This study is for TURP operation for Benign Prostate Hypertrophy patients. When patient comes to the operating room, routine preparations will be made. Haemodynamic parameters and over-the-eye with Optic nerve diameter will be checked with ultrasound before and 10 minutes after spinal anesthesia. Monopolar for patients according to the preference of the surgical team resectoscope technique or bipolar resectoscope technique will be applied. During the operation Blood pressure, pulse minute the number of irrigation solutions used and the amount of intravenously administered serum, operation time will be saved. Optic nerve sheath diameter after the operation would be checked again. intraoperative and postoperative complications in the waking room (respiratory distress, hypotension, hypertension, bradycardia, tachycardia, vomiting, headache, restlessness, seizure, arrhythmia, vision disorder) will be recorded.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
50 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Ages 50-80
  • Planned TUR-P operation

排除标准

  • Heart or respiratory failure
  • Koagülation diathesis
  • Eyedisease related patients

结局指标

主要结局

optic nerve sheath diameter(mm)

时间窗: operation time 3 hours

A linear 10-5 MHz ultrasound probe (GE Healthcare Logiqe Series) was held on the upper eyelid over the gel carefully. Part of the optical nerve that enters the orbital globe was monitorized in the 2D mode without exerting much pressure. Diameter of the optic nerve sheath was measured 3 mm behind the optic disk using an electronic caliper after the right contrast was found between the retrobulber echogenic fatty tissue and the vertical hypoechogenic band

次要结局

未报告次要终点

研究者

发起方
Bursa Yüksek İhtisas Education and Research Hospital
申办方类型
Other Gov
责任方
Principal Investigator
主要研究者

Umran Karaca

Medical Doctor

Bursa Yüksek İhtisas Education and Research Hospital

研究点 (2)

Loading locations...

相似试验