Relining Assessment of Digital and Conventional Fabricated Complete Denture Base
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 12
- 试验地点
- 2
- 主要终点
- Assessment of change in occlusal forces during the follow up period.
研究概览
简要总结
The bond between the resilient denture liner material and the denture base is essential to improve complete denture accuracy and retention to the underlying ridge. The bonding characteristics between resilient denture reline materials and conventional Polymethyl methacrylate (PMMA) denture base polymers have been evaluated extensively. But with the introduction of digital fabricated complete denture, the bond characteristics between digitally fabricated dentures and denture liner is sparse.
详细描述
Dental prostheses fabricated using different digital technology have become popular in recent years. Computer-aided design and computer-aided manufacturing (CAD-CAM) technology provides two techniques, milled or 3D printed technique which simplified the complex dental laboratory procedures by digitalizing the prosthetic design and automating the manufacturing process. Digitally fabricated prostheses have been reported to have excellent accuracy factor that has been related to favorable clinical performance. However, bone resorption underneath any mucosa supported prosthesis is not avoidable. Resilient liners are required for most complete dentures after 6 to 12 months to improve adaptation to the underlying tissues and to reduce the force transmitted to the edentulous ridge during functionThe bond between the resilient denture liner material and the denture base is essential to improve complete denture accuracy and retention to the underlying ridge. The bonding characteristics between resilient denture reline materials and conventional Polymethyl methacrylate (PMMA) denture base polymers have been evaluated extensively. But with the introduction of digital fabricated complete denture, the bond characteristics between digitally fabricated dentures and denture liner is sparse.
Therefore, the aim of this project is to evaluate the bond strength and effectiveness of denture reline of CAD/CAM (milled and 3D printed ) fabricated complete dentures compared to conventional heat-polymerized denture base.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Participant)
盲法说明
the patient is not know the type of prosthesis he will receive
入排标准
- 年龄范围
- 45 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Patients are free from any systemic diseases that might affect neuro-muscular control.
- •Patients having class I maxilla-mandibular relationship
- •Patients having healthy mucosa and normal salivary flow
排除标准
- •Patients have severe bony undercut.
- •Uncooperative patients.
- •Patients having radiation to the head and neck region.
- •Smoker patients.
研究组 & 干预措施
Complete denture fabricated from Conventional heat curing
The patients in this group will receive complete dentures fabricated by conventional heat curing method. and they will receive soft lining of the complete dentures after one year.
干预措施: soft lining of complete denture processed by 3 different techniques. (Other)
complete denture fabricated by CAD/CAM milled technology
The patients in this group will receive complete dentures fabricated by CAD/CAM ( Computer aided design/ Computer aided manufacture) method. and they will receive soft lining of the complete dentures after one year.
干预措施: soft lining of complete denture processed by 3 different techniques. (Other)
complete denture fabricated by CAD/CAM 3D Printed technology
The patients in this group will receive complete dentures fabricated by 3D printing ( three dimension) method. and they will receive soft lining of the complete dentures after one year.
干预措施: soft lining of complete denture processed by 3 different techniques. (Other)
结局指标
主要结局
Assessment of change in occlusal forces during the follow up period.
时间窗: on 3rd month of denture insertion, on 6th month of denture insertion, on the 9th month of denture insertion
Assessment of occlusion equilibrium by Occlusense device
Assessment of change in retentive force of the complete denture
时间窗: on 3rd month of denture insertion, on 6th month of denture insertion, on the 9th month of denture insertion
assessment of complete denture retention by digital force gauge
次要结局
- Patient Satisfaction(on day one of denture insertion and on the 9th month of denture insertion ( end of the follow up period))
研究者
Asmaa Nabil Elboraey
Professor
National Research Centre, Egypt
