跳至主要内容
临床试验/NCT02466282
NCT02466282已完成不适用

A Randomized Controlled Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold

Yonsei University2 个研究点 分布在 1 个国家目标入组 13 人开始时间: 2015年6月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
13
试验地点
2
主要终点
Percentage of uncovered scaffold struts

研究概览

简要总结

It is well-known that non-optimal stent implantation associated with under-expansion or incomplete strut apposition during percutaneous coronary intervention (PCI) leads to a higher incidence of restenosis and stent thrombosis. OCT-guided PCI with metallic stent has previously been shown to be safe and feasible, resulting in better clinical outcomes compared with angiography-only guided PCI. Everolimus-eluting bioabsorbable vascular scaffold (BVS; Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. BVS has a number of proposed advantages over current metallic stent technology. These include elimination of chronic sources of vessel irritation and inflammation, which can reduce the potential risk of late scaffold thrombosis after complete scaffold bioresorption. Although the current generation of the Absorb BVS have larger strut thickness of 150 μm compared with 80 μm of strut of Xience stent, the acute recoil of the polymeric device was similar to that of metallic stent. However, operators tented to use dilating devices less aggressively because of the concerns about limitation in elongation-at-break of polylactide. Previous studies reported 20-30% of under-expansion or malapposition with BVS, which would increase the risk of adverse events including late stent thrombosis. OCT-guidance may improve more optimized scaffold placement and also better outcomes. Therefore, investigators will compare OCT guidance and angiography-only guidance for PCI with BVS regarding incomplete scaffold apposition and neointimal scaffold coverage. Investigators are also going to compare these two strategies regarding clinical outcomes with verification of the cut-off value by OCT-acquired uncovered scaffold rate.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
19 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients ≥ 19 years old
  • Patients with ischemic heart disease who are considered for coronary revascularization with PCI
  • Significant coronary de novo lesion (stenosis > 70% by quantitative angiographic analysis) treated by single BVS ≤ 25mm
  • Reference vessel diameter of 2.5 to 3.5 mm by operator assessment

排除标准

  • Myocardial infarction
  • Complex lesion morphologies such as aorta-ostial, unprotected left main, chronic total occlusion, graft, thrombosis, and restenosis
  • Reference vessel diameter <2.5 mm or >3.5 mm
  • Heavy calcified lesions (definite calcified lesions on angiogram)
  • Lesions requiring 2 or more BVS
  • Contraindication or hypersensitivity to anti-platelet agents or contrast media
  • Treated with any metallic stent or BVS within 3 months at other vessel
  • Creatinine level ≥ 2.0 mg/dL or ESRD
  • Severe hepatic dysfunction (3 times normal reference values)
  • Pregnant women or women with potential childbearing
  • Inability to follow the patient over the period of 1 year after enrollment, as assessed by the investigator
  • Inability to understand or read the informed content

结局指标

主要结局

Percentage of uncovered scaffold struts

时间窗: six months

Percentage of uncovered scaffold struts between OCT guidance vs. angiography-only guidance PCI on 6 month OCT

次要结局

  • Percentage of incomplete scaffold struts apposition(six months after stent implantation)
  • Major cardiac and cerebrovascular adverse events (MACCEs)(until one year)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验