跳至主要内容
临床试验/NCT06543329
NCT06543329
尚未招募
不适用

Comparative Analysis Between Different Suture Materials in Subcuticular Cesarean Wound Closure in Woman With BMI 40 or Greater in Cesarean Delivery: An Interventional Randomized Comparative Clinical Trial

Cairo University1 个研究点 分布在 1 个国家目标入组 300 人开始时间: 2024年8月1日最近更新:

概览

阶段
不适用
状态
尚未招募
入组人数
300
试验地点
1
主要终点
the rate of any documented wound complication during the first six weeks postpartum

概览

简要总结

1.1. Background and Rationale Cesarean section is one of the most common surgical procedures performed worldwide. The choice of suture material for closing the skin incision is crucial, as it can influence wound healing, the risk of wound complications, and the cosmetic outcome. Subcuticular suturing, a technique where the suture is placed just under the skin, is favored for its aesthetic benefits and reduced risk of infection. However, the type of suture material used can significantly impact these outcomes. This study aims to provide a comparative analysis of various subcuticular suture materials used in cesarean sections, focusing on wound complications and incision outcomes.

1.2. Objective of the Study The objective of this study is to compare the incidence of wound complications and the quality of incision outcomes associated with different subcuticular suture materials used in cesarean sections. By doing so, the investigators aim to identify the most effective suture material for minimizing wound complications and optimizing cosmetic results.

详细描述

2.1. Surgical Techniques in Cesarean Section Cesarean section involves multiple surgical steps, including skin incision, uterine incision, and closure of the incisions. The subcuticular suturing technique is often preferred for skin closure due to its potential for better cosmetic results and lower infection rates compared to other methods like staples or interrupted sutures.

2.2. Types of Suture Materials

Suture materials can be broadly categorized into absorbable and non-absorbable, and further into monofilament and multifilament types. Common suture materials used in subcuticular skin closure include:

Absorbable Sutures: Poliglecaprone (Monocryl), Polyglactin (Vicryl), Polydioxanone (PDS).

Non-Absorbable Sutures: Nylon, Polypropylene (Prolene), Silk. 2.3. Previous Studies on Suture Materials in Cesarean Section Previous studies have explored the impact of different suture materials on wound healing, infection rates, and cosmetic outcomes. Research indicates varying results, with some studies favoring absorbable sutures for their reduced need for removal and lower infection rates, while others suggest non-absorbable sutures may provide stronger wound support. However, comprehensive comparative analyses specific to cesarean sections remain limited.

  1. Methodology 3.1. Study Design This study will use a prospective, randomized controlled trial design. Participants undergoing elective cesarean sections will be randomly assigned to receive subcuticular suturing with one of several suture materials.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
20 Years 至 45 Years(Adult)
性别
Female
接受健康志愿者

入选标准

  • Women aged 20-45 years old.
  • BMI = or more than 40 kg/m2
  • Primigravida or not more than the previous 1 cesarean section.
  • Will undergo a lower-segment cesarean section.
  • Hb: ≥ 10 gm/dl.
  • Viable fetus.
  • No history of medical comorbidities.

排除标准

  • History of urogenital tract infection within 2 weeks before cesarean delivery.
  • Presence of clinical signs of infection at the time of delivery including PPROM and intraamniotic infection.
  • Medical comorbidities (hypertension, diabetes, etc.).
  • Hypersensitivity to any of the suture materials.
  • Women with abnormal placentation (placental abruption or placenta previa).
  • History of systemic corticosteroid intake during their pregnancy for 2 weeks or more.
  • History of previous surgical site infection.
  • Immune-compromised women.
  • Women refused to participate in the study or could not obtain consent.

结局指标

主要结局

the rate of any documented wound complication during the first six weeks postpartum

时间窗: 6 weeks

This measure tracks the incidence of wound complications within six weeks postpartum, including infection, dehiscence, seroma, hematoma, ecchymosis, pus, delayed healing, and secondary suture needs. Measurement Tools: Clinical examinations during follow-up visits Patient self-reports Review of medical records Assessment Procedure: Patients will undergo follow-up visits at 2, 4, and 6 weeks postpartum. Complications will be documented through clinical exams, patient reports, and medical record reviews. Calculation: The rate is calculated as the number of patients with any wound complication divided by the total number of patients, expressed as a percentage.

次要结局

  • cosmetics satisfaction(6 weeks)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

ahmed nagy shaker ramadan

lecturer

Cairo University

研究点 (1)

Loading locations...

相似试验