P-max or P-submax? This is the Question! A Prospective Randomized Search of the Most Reliable ECG Landmark for a Long Term Central Venous Catheter.
试验速览
- 阶段
- 4 期
- 状态
- 已完成
- 发起方
- 入组人数
- 326
- 试验地点
- 1
- 主要终点
- Distance between tracheal carina and distal end of the catheter
研究概览
简要总结
Intravenous electrocardiographic guidance (IVECG) is a safe, reliable and accurate technique to correctly position the catheter tip. The investigators sought to evaluate the superiority of the P-maximal (P-max) wave compared to the P-submaximal (P-submax) wave in obtaining a more correct, safer and longer lasting device placement, with a lower incidence of complications and secondary misplacement.
详细描述
This prospective randomized trial was designed to observe the placement of long term iv catheters obtained with the IVECG method. Patients were randomised into 2 groups: in group A the catheter tip was placed in correspondence to the P-max, in group B in correspondence to the P-submax. We followed up the tip position by measuring the variation of its distances from the tracheal carina on multiplanar reconstructions of volumetric CT scans taken within a month (T0) and a year (T1) from the port implant.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Prevention
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •indication to chemo port insertion
- •ability to give informed consent
排除标准
- •younger than 18
- •inability to give consent
- •atrial fibrillation or flutter
- •pace-maker or implantable cardioverter-defibrillator
结局指标
主要结局
Distance between tracheal carina and distal end of the catheter
时间窗: up to 10 months
次要结局
未报告次要终点
研究者
Massimiliano Carassiti
Professor