跳至主要内容
临床试验/NCT02842151
NCT02842151已完成不适用

Optimizing the Assessment of Refractive Outcomes After Cataract Surgery and Implantation of a Monofocal IOL

Alcon Research0 个研究点目标入组 162 人开始时间: 2016年9月21日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
162
主要终点
IOL A-constant at 3 Months at Each Site

研究概览

简要总结

The purpose of this study is to evaluate current available assessments (automated vs. manual) with which manifest refraction data and biometric variables are obtained to understand if data from an automated refractor can be utilized to optimize the A-constant as well as manual subjective refraction (ie, to a clinically insignificant difference). The A-constant is the calculated number that helps the surgeon determine which IOL should be implanted in the eye during cataract surgery.

详细描述

Subjects will be implanted with ACRYSOF® IQ Monofocal IOL Model SN60WF. Standard clinical practice will be followed for pre-operative testing, IOL power estimation and IOL implantation. Only one eye will be enrolled in the study per surgeon determination. The eye will undergo both an automated and manual manifest refraction assessment at 3 months postoperative.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
22 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Able to understand and sign an Ethics Committee/Institutional Review Board approved Informed Consent;
  • Willing and able to attend all scheduled study visits as required per protocol;
  • Diagnosed with cataract in one or both eyes;
  • Planned cataract removal by phacoemulsification with implantation of a monofocal IOL; laser refractive procedures for incisions (primary and sideport), capsulorhexis and lens fragmentation are allowed;
  • Preoperative keratometric astigmatism ≤ 1.0 diopter (D);
  • Other protocol-defined inclusion criteria may apply.

排除标准

  • Women of childbearing potential, pregnant, or breast-feeding;
  • History of ocular pathology, ocular inflammation, or ocular conditions, as specified in the protocol;
  • Previous intraocular or corneal surgery;
  • Use of systemic medications that, in the opinion of the Investigator, may confound the outcome or increase the risk of complications to the subject;
  • Any medical condition that, in the opinion of the Investigator, may confound the results of this study, prohibit the completion of the study assessments, or increase the risk for the subject;
  • Other protocol-defined exclusion criteria may apply.

结局指标

主要结局

IOL A-constant at 3 Months at Each Site

时间窗: Month 3 (Day 80-100) Post Study Eye Implantation

The A-constant, is a type of IOL constant, that accounts for clinical variables that may affect the refractive outcome (e.g. patient factors, biometry method). It relates the power of the IOL to axial length and corneal measurements. It is specific to the design of the IOL, style, and placement within the eye. The optimization of the A-constant is fundamental to achieving the targeted refractive outcomes, offset any observed error and for ensuring high patient satisfaction following cataract surgery. Since errors/noise from refraction plays a significant role in A-constant optimization, it is important to determine if an automated method has any advantages over conventional manifest refraction. A-constants based on autorefraction and manifest refraction for the study eye are compared for each subject. The mean difference between the two methods cannot be greater than 0.15 D at each of the three study centers for the methods to be considered equivalent.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

相似试验