The Use of Multifrequency Bioimpedance Assessments as an Estimate of Perioperative Total Body Volume and Postoperative Fluid Resuscitation
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 86
- 试验地点
- 2
- 主要终点
- Bioimpedance Assessment
研究概览
简要总结
Being able to accurately monitor patient bodily fluid levels during and after surgery is very important, as there are a number of complications that can arise if a patient's fluid levels become unbalanced, such as swelling within or pressure on various bodily organ systems. There are several different ways that physicians can monitor a patient's fluid balance during and after surgery, such as measuring the amount of urine output or the use of central venous catheters which measure the pressure in the veins entering the heart. Most of these techniques are invasive since they require tubes to be inserted into the body. A potential alternative would be to use a noninvasive technique such as electrical bioimpedance (BIA).
Bioimpedance assessments work by using small electrical currents that can accurately predict both the water surrounding the outside of cells in the body, as well as the total amount of water in the entire body. Electrical bioimpedance assessments have been used to estimate patient swelling following surgery (edema), to measure the volume of blood the heart is pumping out, as well as to calculate body fat percentages.
The goal of this study is to relate this technology to fluid shifts within the body that occur as a result of surgery, in particular, major intra-abdominal surgeries. By using bioimpedance during and after surgery, the investigators will compare the data collected with that calculated by using traditional measures of body fluid status, such as urine output and intraoperative blood loss. During the study, the bioimpedance monitors will not replace the standard bodily fluid monitors and will not interfere with their readings. Additionally, the electrical current produced by the bioimpedance monitors is too small for patients to feel and will not interfere with medical devices such as pacemakers.
详细描述
Being able to accurately monitor patient bodily fluid levels during and after surgery is very important, as there are a number of complications that can arise if a patient's fluid levels become unbalanced, such as swelling within or pressure on various bodily organ systems. There are several different ways that physicians can monitor a patient's fluid balance during and after surgery, such as measuring the amount of urine output or the use of central venous catheters which measure the pressure in the veins entering the heart. Most of these techniques are invasive since they require tubes to be inserted into the body. A potential alternative would be to use a noninvasive technique such as electrical bioimpedance (BIA).
Bioimpedance assessments work by using small electrical currents that can accurately predict both the water surrounding the outside of cells in the body, as well as the total amount of water in the entire body. Electrical bioimpedance assessments have been used to estimate patient swelling following surgery (edema), to measure the volume of blood the heart is pumping out, as well as to calculate body fat percentages.
The goal of this study is to relate this technology to fluid shifts within the body that occur as a result of surgery, in particular, major intra-abdominal surgeries. By using bioimpedance during and after surgery, the investigators will compare the data collected with that calculated by using traditional measures of body fluid status, such as urine output and intraoperative blood loss. During the study, the bioimpedance monitors will not replace the standard bodily fluid monitors and will not interfere with their readings. Additionally, the electrical current produced by the bioimpedance monitors is too small for patients to feel and will not interfere with medical devices such as pacemakers.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients having major intra-abdominal procedures under general anesthesia requiring hospitalization postoperatively during the initial recovery from surgery.
排除标准
- •Patients not having intra-abdominal procedures (ie. Thyroidectomy, open or laparoscopic inguinal hernia repair, excision of skin lesions, breast procedures)
- •Patients having outpatient surgery
- •Patients having laparoscopic cholecystectomies, laparoscopic or open appendectomies
- •Patients having bariatric surgery (because the bioimpedance assessment technology has proven to be unreliable in obese populations)
- •Morbidly obese patients (BMI >40)
- •Unable to provide informed consent
- •Pregnant women
研究组 & 干预措施
Bioimpedance Assessment
The only group will be those patients having major intra-abdominal surgical procedures.
Each patient involved in the study will be evaluated with a bioimpedance monitor ('Bodystat Quadscan 4000') to assess total body water, estimated body water, and intravascular body water volume preoperatively, postoperatively, and daily during the postoperative recovery period.
Bioimpedance Assessment
干预措施: Bodystat Quadscan 4000 (Device)
结局指标
主要结局
Bioimpedance Assessment
时间窗: Average measurement, in ohms, taken daily for approximately 8-10 days
Postoperative bioimpedance assessment measurements were recorded for each participant. One average across this time frame was recorded.
次要结局
- Daily Fluid Balance (Intakes and Outputs)(Sum of intakes and outputs each day while inpatient, an average of 8 days)
- Urine Output(preoperative measurement)
- American Society of Anaesthesiologists Physical Status Classification Scale(preoperative)
- Study Characteristics of Participants: Body Mass Index(baseline measurement)
- Amount of Intraoperative Fluids(intraoperative measurement)
- Percent Extracellular Water Volume(6 hours postoperative measurement)
- Percent Intracellular Water Volume(Preoperative measurement)
研究者
Christian McEvoy
General Surgery Resident
United States Naval Medical Center, Portsmouth