Assessments of Diaphragm-pleural Mechanics During the Weaning From Prolonged Mechanical Ventilation
试验速览
- 阶段
- 不适用
- 入组人数
- 200
- 试验地点
- 1
- 主要终点
- Weaning success
研究概览
简要总结
Weaning failure from mechanical ventilator is commonly seen in respiratory failure and increases duration of ventilator use, ICU stay, ventilator associated pneumonia and even mortality. The diaphragm serves as one of the most important respiratory mechanism and its function differs the weaning success rate. Since 1980s, ultrasonography assessment in diaphragm movement were developed and further discussion upon whether it serves as a predicting factor for extubation failure. The measurement includes difference of diaphragm thickness, diaphragm excursion or the movement of liver and spleen.
Multiple studies targeted intubated patients with different measurement methods and all resulted with good weaning prediction value.6 Of all the studies, only one study targeted tracheostomy tube patients. They reported diaphragm thickness fraction >36% as cutoff value is associated with successful spontaneous breathing trial (SBT), with a sensitivity of 0.82, specificity of 0.88. However, little comparison with traditional weaning parameters was mentioned in the study. We designed this prospective observational study to evaluate whether diaphragm movement under ultrasound serves as a predicting index of ventilator discontinuation in patients with tracheostomy. The diaphragm movement will also correlate with other parameters such as RSBI, Pi max, Pe max, Tv spont., WEANSNOW score(WS), VO2, APACHE II. Esophageal pressure is also provided as an option for our study population for more information such as pleural pressure, transdiaphragm pressure, etc.
The ultrasonography measurement of diaphragm movement will be performed within 6 hours before discontinuation of ventilator. The patient remains in semi-recumbent position with the convex probe selected for its good penetration. The probe is placed at a craniocaudal axis, 90 degrees to the skin at the lower intercostal spaces to right anterior axillary line (AAL) and left posterior axillary line (PAL), which allows a perpendicular ultrasound beam direction to the diaphragm movement. Liver (border or vascular structure), splenic (border or vascular structure) will be selected as target point and the marked distance of movement during quiet respiration cycle will be measured 10 times with a largest value calculated. Other echo measurements will also be attempted.
The study aims to investigate if the measurement of the diaphragm movement serves as a reliable predicting factor for weaning failure in respiratory care center patients.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 20 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Prolonged mechanical ventilation with tracheostomy tube
- •Oxygen with a fraction of ≤ 0.4
- •Positive end expiratory pressure at ≤ 5 cm H2O
- •Pressure support at ≤ 8 cmH2O
排除标准
- •No spontaneous breathing
- •Unstable hemodynamic status,
- •History of peritonitis, intraabdominal operation, empyema, or pleurodesis.
结局指标
主要结局
Weaning success
时间窗: 1 month
Liberation from mechanical ventilation
次要结局
- Ventilator free 30 days after liberation(30 days after liberation)
- Ventilator free 60 days after liberation(60 days after liberation)
- Ventilator free 90 days after liberation(90 days after liberation)