跳至主要内容
临床试验/NCT03159377
NCT03159377已完成不适用

Ultra-Low Dose CT Denoising for Lung Nodule Detection

Sheba Medical Center1 个研究点 分布在 1 个国家目标入组 52 人开始时间: 2017年7月4日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
52
试验地点
1
主要终点
Identification of a pulmonary nodule

研究概览

简要总结

We will perform an ultra low-dose CT (ULDCT) in addition to a regular chest CT scan for adult patients undergoing a clinically indicated chest CT. Using a recently developed computationally efficient algorithm for the denoising of ULDCT scans after image reconstruction, we will compare the sensitivity, specificity and accuracy of lesion detection with the ULDCT as compared to the regular CT scan.

详细描述

Patient cohort: Two hundred patients will be recruited for this study. Patients will be comprised of two groups: an inpatient group of patients from the Internal Medicine Department E for which a chest CT is ordered during their hospitalization; and ambulatory patients arriving for an ambulatory chest CT in the early afternoon. The treating clinician ordering the chest CT for the patients from Internal Medicine E will consent the inpatients while a chest radiologist from the Radiology Department will consent the outpatients arriving in the early afternoon for a chest CT study. For inclusion in the study, patients will be adults, older than 18 years old with the ability to follow orders and hold their breath for 8 seconds as determined by the physician at time of study consent.

Imaging method: All patients consented for this study will be imaged on a dedicated scanner for the study, Revolution (GE, Milwaukee, WI). Immediately following the patient's diagnostic chest CT scan, an ultra low dose chest CT scan will be obtained. The routine CT scans of the patients consented for this study will be performed using our routine protocol on the GE Revolution which typically delivers at our institution an average effective dose of 2.9mSv (range 0.95-3.01mSv) while our other Philips routine chest CT scan delivers an average effective dose of 10.5mSv (range 10.29-12.95mSv). With the addition of the ultra low dose technique, which delivers a radiation dose of a range of 0.5-1 mSv (calculated from a pilot study we obtained on pigs), patients are expected to get an total radiation dose for both scans together of about 4 mSv which is less than 10.5mSv (the normal dose for the Phillips CT machine at our institution). Just as a comparison, a meticulous study looking at multiple institutions showed that the average effective dose from a routine chest CT is 7mSv, range 4-18mSv and for a chest CT with pulmonary embolism protocol an average effective dose of 15mSv with a range of 13-40mSv .

Image evaluation: The diagnostic chest CT scan will be sent to the PACS as usual and interpreted immediately, during the same day, as per normal inpatient clinical operations protocol at our institution. The ultra low dose CT scan will be automatically sent to the computational imaging lab processing station, which will denoise the image. After denoising the images will be automatically forwarded to the PACS under the same accession number of the routine chest CT scan. Comparison of the ultra low dose denoised images to the routine chest CT images will be performed by an experienced chest radiologist at a later date, at least one week after date of acquisition to prevent any memorability of the original image. Radiologists' memory of findings has been shown to be poor, even when viewed immediately but slightly worse when time passes [Evans]. The radiologist will document the presence of nodules, consolidation, ground glass opacities, emphysema, fibrosis with abnormalities marked on the images in the PACS. Following completion of the table, the routine chest CT scan will be used as the gold standard for the presence of the imaging findings. The documented ultra low dose CT findings will be compared to the images from the routine chest CT scans. Each finding documented will be individually documented as a true finding if also seen on the routine chest CT scan or false finding if not present on the routine chest CT scan. Additional findings only seen on the routine chest CT scan will be documented as missed findings.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 110 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Any adult patient scheduled for a chest CT, in-patient or outpatient

排除标准

  • 未提供

结局指标

主要结局

Identification of a pulmonary nodule

时间窗: Patient collection in two years

Comparison of sensitivity, specificity and accuracy in identifying a pulmonary nodule when comparing denoised ULDCT to a regular CT.

次要结局

未报告次要终点

研究者

申办方类型
Other Gov
责任方
Principal Investigator
主要研究者

Prof. Edith Marom

Professor

Sheba Medical Center

研究点 (1)

Loading locations...

相似试验