NCT01090934已完成不适用
Etude de la Performance Diagnostique de l'EEG-Haute Résolution Sur la Localisation de la Zone épileptogène Pour le Traitement Chirurgical Des épilepsies Partielles Pharmaco-résistantes
Central Hospital, Nancy, France4 个研究点 分布在 1 个国家目标入组 115 人开始时间: 2009年10月1日最近更新:
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 115
- 试验地点
- 4
- 主要终点
- Sensitivity and specificity of electrical source localization of inter-ictal and ictal discharges using high-Resolution EEG for localizing the epileptogenic zone (the stereo-electroencephalography will be the reference method)
研究概览
简要总结
Multicenter prospective study comparing the diagnosis value of high-resolution EEG and depth-EEG to localize the epileptogenic zone in drug resistant partial epilepsies.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 15 Years 至 —(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •medically intractable patial epilepsy confirmed by video-EEG recordings of epileptic seizures.
- •Depth EEG (Stereo-EEG) required to delineate the epileptogenic zone and define the surgical procedure.
- •full informed consent of the patient (or of his/ her legal representative)
- •15 year or older patient
排除标准
- •contraindication to cortectomy
- •contraindication to depth-EEG
- •indication of epilepsy surgery without depth-EEG monitoring
- •high grade glioma, arterio-veinous malformations
- •pregnancy
- •history of severe cardio-vascular event (coronaropathy, stroke)
结局指标
主要结局
Sensitivity and specificity of electrical source localization of inter-ictal and ictal discharges using high-Resolution EEG for localizing the epileptogenic zone (the stereo-electroencephalography will be the reference method)
时间窗: 3 years
results of electrical sources localization of inter-ictal and ictal discharges are compared to the epileptogenic zone defined by SEEG
次要结局
- inter-observer reliability of electrical source localization of inter-ictal and ictal discharges for localizing the epileptogenic zone.(3 years)
- sensitivity and specificity of high resolution EEG and electrical source imaging for surgical decision(3 years)
研究者
louis maillard
Dr Louis MAILLARD
Central Hospital, Nancy, France
研究点 (4)
Loading locations...
相似试验
终止
不适用
Comparison Between High-density Electroencephalography and Conventional Electroencephalography for Comatose PatientsPost Anoxic ComaNCT02588482Centre Hospitalier Universitaire de Besancon50
撤回
不适用
AI-assisted cEEG Diagnosis of Neonatal Seizures in Neonatal Intensive Care UnitNeonatal SeizureNCT04991779Children's Hospital of Fudan University
尚未招募
不适用
HR-EEG Contribution in Prognostic Evaluation of Language Development in Children With ASDLanguage DevelopmentNeurocognitive DisordersChild LanguageAutism Spectrum DisorderNCT05586672Etablissement Public de Santé Barthélemy Durand120
已完成
不适用
NeuroLex EEG-Based ADHD Assessment Aid, Pivotal StudyAttention Deficit Disorder With HyperactivityNCT00595751Lexicor Medical Technology, LLC300
Unknown
不适用
Frontal Amplitude-integrated Electroencephalogram in Early Prognostication After Cardiac ArrestHeart ArrestNCT03154879Seoul St. Mary's Hospital500