跳至主要内容
临床试验/NCT02589171
NCT02589171已完成不适用

Randomized Trial Evaluating Effectiveness of neoClose Abdominal Closure Device Versus Carter-Thomason Needle Passer

The University of Texas Health Science Center, Houston2 个研究点 分布在 1 个国家目标入组 70 人开始时间: 2016年2月12日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
70
试验地点
2
主要终点
Technical Effectiveness as Assessed by Depth of Needle Penetration to Complete Closure at Both the Camera Port Site and Stapler Port Site

研究概览

简要总结

The purpose of this study is to compare the neoClose abdominal closure to the standard Carter-Thomason closure in a bariatric surgery gastric bypass population.

详细描述

Both the neoClose abdominal closure to the standard Carter-Thomason closure will be used to close 12 mm camera port sites and 12 mm stapler port sites upon completion of a robotic assisted laparoscopic gastric bypass. The procedure requires a 12 mm port site be placed in the midline approximately 3 cm cephalad to the umbilicus and a second 12mm port site in the right mid abdomen. Port sites will be closed as defined as the inability to palpate a fascial defect and the incision being air tight upon carbon dioxide insufflation.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Quadruple (Participant, Care Provider, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Morbid obesity (BMI > 35).
  • Completed multimodality pre operative evaluation (Psychology, Nutrition, Support Groups).
  • Approved for robotic assisted laparoscopic gastric bypass.

排除标准

  • Previous midline laparotomy or weight loss procedure.

研究组 & 干预措施

Neo Close Abdominal Closure

Experimental

干预措施: Neo Close Abdominal Closure (Device)

Carter Thomason Device

Active Comparator

干预措施: Carter Thomason Device (Device)

结局指标

主要结局

Technical Effectiveness as Assessed by Depth of Needle Penetration to Complete Closure at Both the Camera Port Site and Stapler Port Site

时间窗: at the time of surgery

Technical Effectiveness as Assessed by Number of Participants With Surgical Site Occurrences Post-Operatively

时间窗: 6 weeks

Surgical site occurrences include hematoma, seroma, or infection and were assessed by physical exam.

Technical Effectiveness as Assessed by Number of Sutures Required to Complete Closure at the Camera Port Site

时间窗: at the time of surgery

Technical Effectiveness as Assessed by Number of Sutures Required to Complete Closure at the Stapler Port Site

时间窗: at the time of surgery

Technical Effectiveness as Assessed by the Time Required to Complete Closure at the Stapler Port Site

时间窗: at the time of surgery

Technical Effectiveness as Assessed by the Time Required to Complete Closure at the Camera Port Site

时间窗: at the time of surgery

Technical Effectiveness as Assessed by Number of Participants With Presence of Port Site Hernia Post-operatively

时间窗: 6 weeks

Abdominal ultrasound will be used to detect port site hernia.

次要结局

  • Pain at the Stapler Port Site as Assessed by a Visual Analog Scale(6 weeks)
  • Pain as Assessed by Number of Participants Who Took Pain Medications(week 6)
  • Pain at the 12mm Camera Port Site as Assessed by a Visual Analog Scale(6 weeks)
  • Hospital Stay Duration(from the the time of hospital admission to the time of hospital discharge (about 1.29 to 2.95 days))

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Shinil Shah

Assistant Professor

The University of Texas Health Science Center, Houston

研究点 (2)

Loading locations...

相似试验