CONDUCTion System Pacing Versus Biventricular Pacing After Atrioventricular Node Ablation in Heart Failure Patients With Symptomatic Atrial Fibrillation and Narrow QRS (CONDUCT-AF Trial)

University Medical Centre Ljubljana20 个研究点 分布在 7 个国家目标入组 82 人开始时间: 2023年7月18日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
82
试验地点
20
主要终点
Change in left ventricular ejection fraction.

研究概览

简要总结

Atrioventricular node ablation (AVNA) with biventricular (BiV) pacemaker implantation is a feasible treatment option in patients with symptomatic refractory atrial fibrillation and heart failure. However, conduction system pacing (CSP) modalities, including His bundle pacing and left bundle branch pacing, could offer advantages over BiV pacing by providing more physiological activation. The randomized, interventional, multicentric study will explore whether CSP is non-inferior to BiV pacing in echocardiographic and clinical outcomes in heart failure (EF <50%) patients with symptomatic AF and narrow QRS scheduled for AVNA.

详细描述

Atrio-ventricular node ablation (AVNA) with subsequent permanent pacemaker implantation provides definite rate control and represents an alternative therapeutic approach in patients with symptomatic atrial fibrillation (AF) and rapid ventricular rate, refractory to optimal medical treatment or catheter ablation. However, optimal pacing modality remains unclear. Previous studies have demonstrated that biventricular (BiV) pacing followed by AVNA resulted in significant reduction in mortality, heart failure (HF) hospitalizations, significant improvement in symptoms and left ventricular (LV) remodeling. Although, its benefit was much less transparent in patients with narrow QRS and LV impairment, as it still causes abnormal cardiac activation with potential worsening of electrical dyssynchrony. To avoid the detrimental effects of BiV pacing a new concept, conduction system pacing (CSP), including His bundle Pacing (HBP) and left bundle branch pacing (LBBP), was proposed as a potential alternative. Both CSP modalities offer advantages over BiV pacing by providing more physiological activation, avoiding cardiac dyssynchrony and left ventricular dysfunction. Moreover, LBBP showed some advantages over HBP. Since the lead is implanted in the region of the left bundle, which has an adequate distance from the AVNA site, this modality could minimize the risk of increase in capture threshold after AVNA. Additionally, the pacing parameters of LBBP were stable in long-term follow-up studies precluding the need for back-up pacing. Therefore compared to HBP and BiV pacing, LBBP may offer a more feasible physiologic pacing option to be adopted into clinical practice. Some observational studies have already shown positive outcomes of HBP and LBBP in symptomatic AF patients who underwent AVNA with the favorable clinical and echocardiographic improvement compared to BIV pacing, especially in HF patients with narrow baseline QRS and reduced ejection fraction (EF<50%). However, prospective randomized study evaluating the value of CSP as an alternative approach to BiV pacing in combination with AVNA is lacking.

The purpose of this study is to compare the effects of CSP and conventional BiV pacing on echocardiographic and clinical outcomes in HF patients with symptomatic AF and narrow QRS scheduled for AVNA. In this multicentric study, 82 patients will be randomized into one of two arms: a BiV pacing arm with BiV pacemaker implantation + AVNA or CSP arm with the implantation of a CSP device + AVNA. In patients randomized in CSP group, LBBP will be the preferred pacing technique. If LBBP will be unobtainable, HBP implantation will be attempted. In both arms additional defibrillator backup will be implanted at the discretion of the physician according to the ESC guidelines. In short-term analysis after 6 months, echocardiographic, laboratory and symptomatic parameters will be evaluated. Long-term analysis to assess HF hospitalization, cardiovascular mortality and pacing parameters will be performed after at least 24 months of follow-up.

Investigators hypothesize that CSP could represent a feasible and safe alternative to BiV pacing in terms of clinical and echocardiographic outcomes.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Symptomatic permanent atrial fibrillation, refractory to drug therapy or failed catheter ablation
  • Left ventricular ejection fraction <50%
  • Narrow intrinsic QRS ≤ 120 ms
  • NT-proBNP > 600 ng/L
  • Patient has provided written informed consent
  • Age between 18 years and 85 years

排除标准

  • Pre-existing permanent pacemaker, implantable cardioverter-defibrillator or cardiac resynchronization device. Patients who had devices implanted that had <5% of paced beats (i.e., backup pacing) can be enrolled.
  • Life expectancy less than 12 months
  • Severe concomitant non-cardiac disease
  • Recent (<3 months) myocardial infarction, percutaneous or surgical myocardial revascularization
  • Significant heart valve disease (severe insufficiency or stenosis)
  • Contraindication for oral anticoagulation
  • Mechanical tricuspid valve replacement
  • Unwillingness to participate or lack of availability for follow-up

研究组 & 干预措施

Biventricular pacing + AV node ablation

Active Comparator

Implantation of biventricular pacemaker with or without defibrillator lead placement followed by AV node ablation. Optimal guidelines-based heart failure treatment.

干预措施: Biventricular pacemaker implantation (Device)

Biventricular pacing + AV node ablation

Active Comparator

Implantation of biventricular pacemaker with or without defibrillator lead placement followed by AV node ablation. Optimal guidelines-based heart failure treatment.

干预措施: AV node ablation (Procedure)

Conduction system pacing + AV node ablation

Experimental

Implantation of permanent pacemaker with conduction system pacing (preferably left bundle branch) with or without defibrillator lead placement followed by AV node ablation. Optimal guidelines-based heart failure treatment.

干预措施: Conduction system pacing device implantation (Device)

Conduction system pacing + AV node ablation

Experimental

Implantation of permanent pacemaker with conduction system pacing (preferably left bundle branch) with or without defibrillator lead placement followed by AV node ablation. Optimal guidelines-based heart failure treatment.

干预措施: AV node ablation (Procedure)

结局指标

主要结局

Change in left ventricular ejection fraction.

时间窗: baseline and 6 months

Simpson's method assessed with echo.

次要结局

  • Change in clinical parameters(baseline and 6 months)
  • Improvement in clinical parameters(baseline and 6 months)
  • Change in 6-Minute walk test.(baseline and 6 months)
  • Laboratory parameters.(baseline and 6 months)
  • Procedural-related characteristics.(peri-procedural)
  • Procedure-associated adverse events.(peri-procedural, 30 days after the procedure)
  • Need for procedural reintervention.(at least 24 months)
  • ECG parameters.(before and after the procedure)
  • Pacing parameters.(peri-procedural, at least 24 months)
  • Number of detected sustained VT/VF.(at least 24 months)
  • Time to the first occurrence of worsening heart failure.(at least 24 months)
  • Time to cardiovascular death.(at least 24 months)
  • Time to the first occurrence of worsening heart failure or cardiovascular death.(at least 24 months)
  • Number of heart failure hospitalizations.(at least 24 months)
  • Change in LV end-diastolic and end-systolic volume index.(baseline and 6 months)