跳至主要内容
临床试验/NCT05081895
NCT05081895已完成不适用

Ventilation and Perfusion in the Respiratory System

University of California, San Diego1 个研究点 分布在 1 个国家目标入组 16 人开始时间: 2021年8月19日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
16
试验地点
1
主要终点
Distribution of ventilation

研究概览

简要总结

Respiratory failure occurs when the lung fails to perform one or both of its roles in gas exchange; oxygenation and/or ventilation. Presentations of respiratory failure can be mild requiring supplemental oxygen via nasal cannula to more severe requiring invasive mechanical ventilation as see in acute respiratory distress syndrome (ARDS).It is important to provide supportive care through noninvasive respiratory support devices but also to minimize risk associated with those supportive devices such as ventilator induced lung injury (VILI) and/or patient self-inflicted lung injury (P-SILI). Central to risk minimization is decreasing mechanical stress and strain and optimizing transpulmonary pressure or the distending pressure across the lung, minimizing overdistention and collapse. Patient positioning impacts ventilation/perfusion and transpulmonary pressure. Electrical impedance tomography (EIT) is an emerging technology that offers a noninvasive, real-time, radiation free method to assess distribution of ventilation at the bedside. The investigators plan to obtain observational data regarding distribution of ventilation during routine standard of care in the ICU, with special emphasis on postural changes and effects of neuromuscular blockade, to provide insight into ventilation/perfusion matching, lung mechanics in respiratory failure, other pulmonary pathological processes.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 18 years or older
  • admitted to UC San Diego La Jolla or Hillcrest Campus Intensive Care Units
  • Patient requiring supplemental oxygen (including but no limited to nasal cannula, high flow devices, noninvasive positive pressure ventilation or mechanical ventilation

排除标准

  • <18 years
  • Chest wall, anatomical, physical abnormalities, skin integrity issues precluding placement of electrode belt in direct contact with skin
  • Patient is too unstable to position the belt/electrodes or tolerate head of bed changes
  • Confirmed or suspected intracranial bleed, stroke, edema
  • Active implants (i.e. implantable electronic devices such as pacemakers, cardioverter defibrillators, neurostimulators) or if device compatibility is in doubt
  • Pregnant or lactating patients as safety and efficacy for use of EIT in such cases has not been verified

结局指标

主要结局

Distribution of ventilation

时间窗: change from baseline at 15 minutes and 1 hour

Regional ventilation distribution differences measured through electrical impedance tomography (EIT)

次要结局

  • Lung mechanics(Baseline, then at 15 minutes and 1 hour)
  • Blood Gas Partial Pressure of Carbon Dioxide (PaCO2) (mmHg)(Up to 48 hours)
  • Oxygenation(Up to 48 hours)
  • Blood Gas pH(Up to 48 hours)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Alex Pearce

Principal Investigator

University of California, San Diego

研究点 (1)

Loading locations...

相似试验