DRKS00010464已完成未知
Cystovolumetry via Bioimpedancetomography/-spectroscopy in Spinal Cord Injured and Overactive Bladder Patients - UroWatch
Klinik für Paraplegiologie0 个研究点目标入组 13 人开始时间: 2016年5月13日最近更新:
适应症
试验速览
- 阶段
- 未知
- 状态
- 已完成
- 发起方
- 入组人数
- 13
研究概览
简要总结
暂无简介。
研究设计
- 研究类型
- Interventional
- 分配方式
- N/a: Single Arm Study
- 盲法
- Open (masking not used)
入排标准
- 年龄范围
- 18 Years 至 65 Years(—)
- 性别
- All
入选标准
- •Study participant is legally competent and capable of following instructions of the study staff;
- •Signed declaration of consent;
- •Maximal bladder volume > 300ml;
- •Bladder emptying via intermittent self- or assisted catheterization;
- •Micturition impairment because of spinal cord injury
排除标准
- •Bladder cancer;
- •Bladder infection requiring immediate treatment;
- •Kidney disease;
- •Chronic renal insufficiencty;
- •Ascites or soft-part oedema;
- •Metallic implants in electrode attachment area, or electrically active implants;
- •Large accident scars or Caesarean in electrode attachment area;
- •Open wounds in electrode attachment area;
- •Adipositas > grade II;
- •Diabetes mellitus / insipidus;
- •Fear of electrical devices;
- •Bladder emptying via subrapubic catheter;
- •Autonomic dysreflexia;
- •Strong belly spasms, strong clonus;
- •Bladder prolapse grade III and IV;
- •In female participants: currently pregnant
研究者
相似试验
Enrolling By Invitation
不适用
Volume status by bioimpedance spectroscopy assessment in hypertensive chronic kidney disease patientsChronic kidney disease patient stage 3LJ who never recieved renal replacement therapy and diagnosed hypertensionChronic kidney disease Hypertension Bioimpedance spectroscopy volume overload central blood pressure pulse wave velocityTCTR20170329001Division of Nephrology, Depatment of medicine, Faculty of Medicine, Chulalongkorn University46
已完成
不适用
Application of EIT to determine bladder volumeHealthy volunteerselectrical impedance tomography, non-invasive, urinary bladder volume, ultrasoundDRKS00012871Klinik für UrologieUniklinik RWTH Aachen10
已完成
不适用
tility of measuring intravesical urine volume at the perioperative period and validation of accuracy of Lilium alpha-200 for ultrasonic diagnostic imaging system for bladderKnee surgeryJPRN-UMIN000032155Tokai University School of Medicine, Anesthesiology30
Unknown
不适用
Noninvasive Assessment of Intravascular Volume Status for Postoperative PatientsIntravascular VolumeNCT03766451Beni-Suef University35
已完成
不适用
Volume measurement of urinary stones with CTN20.0Calculus of kidneyDRKS00009403niversitätsklinikum FreiburgDepartment ChirurgieKlinik für Urologie100