PET/MRI to Enhance Precision Guidance in Head and Neck Radiation Treatment Planning
试验速览
- 阶段
- 不适用
- 状态
- 终止
- 入组人数
- 3
- 试验地点
- 1
- 主要终点
- Percentage of participants able to complete the PET/MRI examination
研究概览
简要总结
The purpose of this study is to evaluate this new technology available at the University of Wisconsin Carbone Cancer Center in the setting of head and neck cancer radiation treatment planning. This study will also provide preliminary data critical to the development of multi-parametric, multi-modality quantitative imaging biomarkers and data analysis models for prediction of outcome in both tumors and normal tissue, which are essential for patient-specific adaptive therapy.
All participants will undergo a diagnostic PET/CT and a Radiation Treatment Planning CT per SOC procedures. In addition, all participants will undergo an additional imaging set consisting of a PET/MRI. It is anticipated that most patients will undergo the PET/MRI on the same day as their PET/CT negating the need for a second injection of the FDG radioisotope used for SOC PET imaging. All patients will receive gadolinium contrast per SOC dosing guidelines for the MRI portion of the PET/MRI. Both SOC MMRI pulse sequences and investigational sequences will be utilized in this study.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Participants with tumors of the head and neck region (nasal cavity, oral cavity, pharynx, larynx, sinuses, salivary glands, and head and neck skin) who are candidates for radiation treatment.
排除标准
- •Contraindications for MRI: All patients will be screened with standard UWHC MRI screening procedures:
- •Any person with the following will be excluded: cardiac pacemaker, metal fragments in or around the eye, venous umbrella, permanent eyeliner or permanent artificial eyebrows.
- •Patents with the following potentially non-MRI compatible devices will undergo screening using the standard UWHC MRI screening protocol by trained UWHC personnel: cardiac pacemaker, heart valve replacement, intracranial aneurysm clips, middle ear, eye, joint, or penile implants, joint replacements, implantable hearing aids, neurostimulator devices, insulin pumps, shunts/stents, metal mesh/coil implants; metal plate/pin/screws/wires, or any other metallic implants. Also patients with anatomical constraints limiting the feasibility of MRI will be excluded.
- •Issue of pregnancy: We will exclude all known pregnant females from the study to avoid the potential risk of fetal injury upon exposure to the PET scan. Determination of pregnancy will be based upon the standard screening procedures in place for radiation therapy.
- •Persons who are not fluent in English
- •Anyone who can not provide written informed consent
结局指标
主要结局
Percentage of participants able to complete the PET/MRI examination
时间窗: Up to 1 year
Identify the percentage of head and neck cancer patients who are able to successfully complete or partially complete the PET/MRI examination. Responses to a 7 point Likert scale will be analyzed with a chi-squared test.
次要结局
- Feasibility of PET/MRI in radiation treatment planning workflow(Up to 1 year)
- Compare conventional MRI pulse sequences to investigational MRI pulse sequences for tumor conspicuity and image quality(Up to 1 year)
- Compare changes in simulated radiation treatment volume when derived from PET/MRI vs PET/CT (GTV, CTV, PTV)(Up to 1 year)
- Changes in staging between PET/CT and PET/MRI(Up to 1 year)