Collection of CT Images to Evaluate Bone Quality Before Total Shoulder Arthroplasty
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 200
- 试验地点
- 1
- 主要终点
- Intra-op bone quality evaluation: Broach Test
研究概览
简要总结
The objective of the study is to evaluate the preoperative bone quality assessment based on CT to later establish a scale for the decision of stemless shoulder arthroplasty.
详细描述
The primary endpoint is the collection of the preoperative CT scan with a calibration phantom at each site and the surgeon's intraoperative evaluation of bone quality. Therefore, this study is not centered around a specific device and any primary shoulder arthroplasty system from Zimmer Biomet including anatomical, hemi, or reverse, stemmed or stemless configurations can be used for the target population. The indications of this study are the shoulder joint diseases such as osteoarthritis and the irreparable rotator cuff tears which are needed with TSA/RSA. The subjects should be also met the inclusion/exclusion criteria. The safety of the system will be assessed by monitoring the frequency and incidence of adverse events.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Basic Science
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patient must be older than 18 years and skeletally mature.
- •Patient must undergo the SHA, TSA, or RSA according to the Instructions for Use (IFU).
- •Patient must be anatomically and structurally suited to receive shoulder arthroplasty implants.
- •Patient is a candidate for lateral or bi-lateral shoulder arthroplasty due to one or more of the following:
- •Non-inflammatory degenerative joint disease including osteoarthritis.
- •Avascular necrosis of the humeral head.
- •Autoimmune disease including rheumatoid arthritis.
- •Irreparable rotator cuff tears.
- •Correction of functional deformity.
- •Patient must be able and willing to sign the IRB/EC approved informed consent.
- •Patient must be able to undergo a preoperative CT scan
- •Patient must be willing to share their CT images with sponsor
排除标准
- •Patient is a candidate for shoulder arthroplasty due to one or more of the following:
- •Fractures of the proximal humerus, where other methods of treatment are deemed inadequate.
- •Revision TSA/RSA after the prior TSA/RSA.
- •Patient has experienced the traumatic fractures to the implant site.
- •Patient is unwilling or unable to give consent
- •Patient has any condition which would in the judgement of the Investigator, place the patient at undue risk or interfere with the study, e.g., any neuromuscular disease compromising the affected limb.
- •Patient is known to be pregnant or breastfeeding.
- •Patient is a vulnerable subject (prisoner, mentally incompetent or unable to understand what participation to the study entails, a known alcohol or drug abuser, and/or anticipated to be non- compliant).
- •Patient is uncooperative or patient with neurologic disorders who is incapable or unwilling to follow directions.
- •Patient has any sign of infection affecting the shoulder joint or in its proximity which may spread to the implant site.
- •Patient has rapid joint destruction, marked bone loss, or bone resorption apparent on roentgenogram.
结局指标
主要结局
Intra-op bone quality evaluation: Broach Test
时间窗: Intra-op
The third test is the Broach (or Puncher test) where the impactor is wiggled to assess bone quality. If the puncher is unstable after impaction, then the bone is soft/weak, and a stemmed prosthesis is recommended.
CT scan data acquisition
时间窗: Immediate post-op
The primary endpoint is the collection of the preoperative CT scan with a calibration phantom at each site and the surgeon's intraoperative evaluation of bone quality.
Intra-op bone quality evaluation: Thumb Test
时间窗: Intra-op
The first test is the Thumb test that occurs just after the head resection. The surgeon presses his/her thumb on the resected humeral surface to assess bone quality. If he can depress the thumb into the humerus without much resistance, then primary stability of the stemless implant may be insufficient.
Intra-op bone quality evaluation: Pin Test
时间窗: Intra-op
The second test is the Pin test where the central pin used to position the trial head is wiggled to assess bone quality. If the central pin is unstable in the humerus, then this may indicate that the bone is soft/weak.
Duplicate CT scan data acquisition (Optional)
时间窗: Immediate post-op
Additional primary endpoint for a sub-cohort of a maximum of 30 patients. These patients will receive a second preoperative CT scan after a changing position (patient repositioning), which is needed to evaluate the precision of the phantom-less method. This duplicated scan is considered optional in the study.
次要结局
未报告次要终点