Whole-Body 3D T1-weighted MR Imaging Anatomical Sequences: GE mDixon vs FSE (View) Approaches in Prostate Cancer. Comparison of Diagnostic Performance of GE mDixon and FSE, for Bone and Node Staging in Patients With Prostate Cancer.

Cliniques universitaires Saint-Luc- Université Catholique de Louvain2 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2016年12月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
30
试验地点
2
主要终点
Diagnostic performances of 3D GE T1 sub-sequences

研究概览

简要总结

This study will assess and compare the diagnostic performances and image quality of two WB 3D T1-weighted MR imaging sequences for bone and node staging in patients with prostate cancer : the FSE sequence and a gradient echo (GE) sequence. The latter sequence's main feature is its acquisition time of approximately 1.5 minutes, compared to 18 min for the FSE sequence, reducing the exam's acquisition time, patient discomfort and increasing machine availability.

详细描述

Whole-body (WB) magnetic resonance (MR) imaging has increasingly been used for the screening of bone and soft-tissue metastases in patients with prostate cancer (1). A limitation for its implementation is the 45-60 minutes duration of current WB MRI examinations. Conventional WB MR imaging studies consisted of anatomical two-dimensional (2D) T1-weighted and fat-suppressed fluid-sensitive (proton-density fat-saturated (PDFS) or short-tau inversion-recovery (STIR)) and of a functional diffusion-weighted imaging sequence. Recent research has confirmed the feasibility of replacing the 2D anatomical sequences by a single three-dimensional (3D) T1-weighted fast spin echo (FSE) sequence (2).

This study will assess and compare the diagnostic performances and image quality of two WB 3D T1-weighted MR imaging sequences for bone and node staging in patients with prostate cancer : the FSE sequence and a gradient echo (GE) sequence. The latter sequence's main feature is its acquisition time of approximately 1.5 minutes, compared to 18 min for the FSE sequence, reducing the exam's acquisition time, patient discomfort and increasing machine availability.

The aim of this study is to evaluate the feasibility of the replacement of the WB 3D T1-weighted FSE MR imaging sequence by the WB 3D T1-weighted GE MR imaging sequence.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 99 Years(Adult, Older Adult)
性别
Male
接受健康志愿者

入选标准

  • prostate cancer with high risk for metastases

排除标准

  • contraindications to MRI

研究组 & 干预措施

Diagnostic performance 3D T1

Other

A 3D T1-weighted GE mDixon MR imaging sequence will be added to the routine 3D T1-weighted FSE sequence. mDixon sub-sequences (Fat and In Phase) are compared to 3D T1-weighted FSE in terms of diagnostic accuracy for M and N staging in prostate cancer patients: Fat, In Phase, Fat+In Phase and the routine 3D T1 will be analyzed separately, blindly and randomly.

干预措施: Diagnostic performance 3D T1 (Diagnostic Test)

结局指标

主要结局

Diagnostic performances of 3D GE T1 sub-sequences

时间窗: 3 months