Study of the Effectiveness of Central Line Placement Using an Ultraportable Ultrasound Device

Centre Chirurgical Marie Lannelongue2 个研究点 分布在 1 个国家目标入组 238 人开始时间: 2023年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
238
试验地点
2
主要终点
length of the procedure

研究概览

简要总结

The placement of a catheter in a large-caliber vein is sometimes necessary for the administration of treatments or the monitoring of a patient. This may be associated with complications during its realization, such as the puncture of an adjacent artery with possible formation of a hematoma or the puncture of the pleura with creation of a pneumothorax. These complications may be favored by variations in the anatomy. The use of ultrasound allows visualization of the vessels, its adjacent structures and the puncture needle along its path.

The contribution of ultrasound with the technique of venipuncture under ultrasound guidance is to date the best means of preventing complications by reducing the risk of early mechanical complications by a factor of 5 to 10 according to the studies. The retrospective, multicenter, observational study recently published by Björkander et al reported the experience of 8 Swedish hospitals with 14243 central venous catheter placements, 58% of which were in the internal jugular vein. Nearly one catheter in two was placed with the use of ultrasound (49%). One hundred and eighteen mechanical complications were recorded, of which 23 were considered serious, including 21 pneumothoraxes and 2 severe hemorrhages. Lack of ultrasound use was found to be an independent risk factor for complications in multivariate analysis by logistic regression. Despite a high level of evidence in the scientific literature on the contribution of ultrasound guidance for the placement of central venous catheters, and the recommendations of national and international learned societies published before the start of this study, almost one patient in two had not yet benefited from this technique, which could nevertheless greatly reduce the incidence of early mechanical complications.

The recent introduction of ultra-portable ultrasound scanners could encourage the generalization of the use of ultrasound, given their reduced cost. The hypothesis of the research is that the placement of a central venous catheter is similar whether the ultrasound machine is an ultra-portable ultrasound machine or a conventional ultrasound machine

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age ≥ 18 years
  • Patients scheduled to have a right or left jugular central venous line placed preoperatively or in the ICU .
  • Patient with free, informed and express consent or emergency procedure

排除标准

  • Absolute emergency not allowing randomization
  • Pregnant woman
  • Patient with suspected or proven jugular thrombosis at the insertion site
  • Change of central venous line on guidewire
  • Operator with no experience in central venous line placement under ultrasound
  • contraindication to the placement of a jugular central venous line

结局指标

主要结局

length of the procedure

时间窗: 1 day

the time in seconds between the beginning of the ultrasonographic scan after placement of the sterile protection device and the beginning of fixation of the catheter to the skin after ultrasound verification confirming its correct position.

次要结局

未报告次要终点