跳至主要内容
临床试验/NCT02025543
NCT02025543已完成不适用

Confounder-Corrected Quantitative Magnetic Resonance Imaging (MRI) Biomarker of Hepatic Iron Content

University of Wisconsin, Madison4 个研究点 分布在 1 个国家目标入组 207 人开始时间: 2015年8月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
207
试验地点
4
主要终点
Calibration curve of liver R2* vs LIC measured by Ferriscan at each of the sites

研究概览

简要总结

The purpose of this multi-site research is to validate a rapid magnetic resonance based confounder-corrected R-2 mapping method as a quantitative imaging biomarker of liver iron concentrations.

详细描述

This multi-center, multi-vendor study will validate a rapid magnetic resonance-based confounder-corrected R2* mapping method as a quantitative imaging biomarker of liver iron concentration (LIC). Excessive accumulation of iron in various organs, including the liver, which affects both adult and pediatric populations, is toxic and requires treatment aimed at reducing body iron stores. Measurement of LIC is critical for detection and staging of iron overload, and for monitoring iron-reducing chelator therapies that are expensive and have side effects. Magnetic Resonance Imaging (MRI) is a widely available, accessible, and safe technology, and it is very sensitive to the presence of iron in tissue. Translation of an MRI biomarker of liver iron concentration into broad clinical use requires that it is clinically feasible, precise, robust to changes in scan parameters, calibrated to a validated reference standard of LIC, and is reproducible across sites and manufacturers. There are currently no available MRI methods that meet these requirements. R2*-MRI holds the greatest promise to meet these requirements. R2* mapping can be performed very rapidly with whole-liver 3D coverage in a single 20s breath-hold.

Protocol Modification approved to include additional liver susceptibility measurements for approximately 10 participants (already enrolled at the UW) via recently acquired Superconducting Quantum Interference Device (SQUID). The completion of this additional imaging will depend upon the successful set up and installation of this device.

Per a protocol amendment approved on 10/11/21, the investigators are re-opening the study and increasing enrollment for control subjects. Up to 20 control subjects (changed from 5) will be enrolled.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
8 Years 至 89 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • know or suspected iron overload
  • minimum age: Stanford- 8years , University of Wisconsin - 10 years, John Hopkins follow- 10 years, University of Texas-Southwestern - 18 years

排除标准

  • contraindication to magnetic resonance imaging

结局指标

主要结局

Calibration curve of liver R2* vs LIC measured by Ferriscan at each of the sites

时间窗: 1 year

The hypothesis is that equivalence between R2 measured with different protocols with higher repeatability than standard MRI iron imaging measurement and with linear calibration to liver iron concentration will be demonstrated. This project will be considered a success if the reproducibility of confounder-corrected R2 MRI is established: the hypothesis is that calibrations at all sites will be equivalent.

次要结局

  • Diagnostic Accuracy(2 years)
  • Precision: Difference in UW-measured R2* vs Average(2 years)
  • Robustness Assessed via Linear Mixed Effects Regression(2 years)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验