Evaluating the Correction of Non-invasive Estimated Continuous Cardiac Output in Cardiac Surgical Patients

National Cheng-Kung University Hospital1 个研究点 分布在 1 个国家开始时间: 2012年6月最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
试验地点
1
主要终点
The correlation of esCCO and the traditional CO measurement in cardiac surgical patients.

研究概览

简要总结

In one previous study, esCCO was compared with continuous thermodilution CO (TDCO), measurements in 36 postoperative cardiac surgery patients, showing a bias (mean difference) of -0.06 and a precision (1 SD) of 0.82 L/min. In addition, esCCO was compared with intermittent bolus TDCO, showing a correlation coefficient of 0.82 (P < 0.001, n = 24), a bias of -0.63, and a precision of 1.01 L/min (n = 119). The results of clinical use of esCCO suggest that its measurement accuracy is comparable to the thermodilution method in general population. However, no any intraoperative comparison for cardiac surgery patients was reported before. This study is designed for the accuracy in the patients undergoing cardiac surgery.

Specific aims:

  1. To investigate the correlation of esCCO and the traditional CO measurement in cardiac surgical patients.
  2. To investigate the intraoperative t accuracy of time point between ecCCO and traditional CO measurement for patients undergoing bypass cardiac surgery.

详细描述

Determination of cardiac output (CO) is often desirable for assessing a patient's hemodynamic condition during the surgery requiring cardiopulmonary bypass. However, the current methods of continuous CO measurement are still based on invasive technique, such as thermodilution via pulmonary artery catheter (Swan-Ganz), transpulmonary thermodilution via PiCCO kit, or pulse contour analysis via arterial line (FloTrac or PiCCO). Noninvasive CO measurement to all patients is currently impractical, because most measurement methods available are based on invasive techniques. However, two developing trends for this kind of monitor had occurred. There are one shifting toward noninvasive technologies and the other trend toward continuous measurement rather than intermittent measurement. Therefore, continuous CO (CCO) monitoring with less invasive would be desirable.

The pulse contour method is one of the technologies used for min-invasive monitoring of CO. It is based on the relationship between arterial blood pressure and stroke volume and has been greatly improved since early 1950s. Arterial waveform-based CO is frequently used in current medical practice, but it still requires arterial puncture. Pulse wave transit time has been proven to have good correlation with stroke volume. Pulse wave transit time consists of a pre-ejection period, pulse wave transit time through the artery, and pulse wave transit time through the peripheral arteries, which compensates for the effect of changes in systemic vascular resistance (SVR). Based on the relationship between pulse wave transit time and stroke volume, the noninvasive device, estimated CCO (esCCO), via measuring electrocardiogram (ECG), pulse oximeter wave, and arterial blood pressure had been developed by Sugo et al.. It has the great advantage to simplify CO measurement by combining the results of these familiar noninvasive monitoring techniques. Thus, it may be a useful technique for optimizing medical treatment.

In one previous study, esCCO was compared with continuous thermodilution CO (TDCO), measurements in 36 postoperative cardiac surgery patients, showing a bias (mean difference) of -0.06 and a precision (1 SD) of 0.82 L/min. In addition, esCCO was compared with intermittent bolus TDCO, showing a correlation coefficient of 0.82 (P < 0.001, n = 24), a bias of -0.63, and a precision of 1.01 L/min (n = 119). The results of clinical use of esCCO suggest that its measurement accuracy is comparable to the thermodilution method in general population. However, no any intraoperative comparison for cardiac surgery patients was reported before. This study is designed for the accuracy in the patients undergoing cardiac surgery.

Specific aims

  1. To investigate the correlation of esCCO and the traditional CO measurement in cardiac surgical patients.
  2. To investigate the intraoperative t accuracy of time point between ecCCO and traditional CO measurement for patients undergoing bypass cardiac surgery.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients undergo cardiac surgery and are over 18 years of age.
  • Patients need bypass machine for their cardiac surgery and traditional CO measurement.
  • Patients who are competent to understand the study and provide written informed consent and participate in outcome measurements.

排除标准

  • Patients are over 75 years of age. Patients are unable to read or write the informed consent, any condition that could interfere with the interpretation of outcome assessments, pregnant or lactating women. Patient with marked arrhythmias, those preoperatively receiving treatment with intra-aortic balloon bump (IABP) will also not be included.

结局指标

主要结局

The correlation of esCCO and the traditional CO measurement in cardiac surgical patients.

时间窗: 18 months

1. Comparison Between esCCO and Thermodilution Measurements of CO for cardiac surgical patients. 2. Check the accuracy of esCCO in cardiac surgical patients. It should be well correlated before bypass but will be inaccurate when partial bypass once start. When bypass procedure start to rewarm, it will be accurate initially but gradually well correlated within temperature corrected or heart function become normal again.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Yen Chin Liu

Visiting Staff, Department of Anesthesiology Chief

National Cheng-Kung University Hospital