Anatomic Dynamics of the Internal Iliac Artery After Placement of Iliac Branched Devices Using ECG-gated Computer Tomography Angiography Imaging (IBD-dynamics)

Rijnstate Hospital3 个研究点 分布在 1 个国家目标入组 45 人开始时间: 2016年10月5日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
45
试验地点
3
主要终点
Mobility of hypogastric artery during cardiac cycle (sub study A)

研究概览

简要总结

The incidence of isolated common iliac artery (CIA) aneurysms is low, but in combination with an abdominal aortic aneurysm (AAA) they are found in approximately 20-40% of cases. Basically, two different endovascular strategies can be applied to treat a CIA aneurysm with, including 1. the coverage and 2. the preservation of blood flow to the internal iliac artery (IIA). Coil and coverage of the IIA is related to ischemic complications, including buttock claudication, erectile dysfunction and the more severe spinal and colonic ischemia. Iliac branched devices (IBD) have been developed to exclude CIA aneurysms preserving the IIA and currently three alternatives are on the market. Clinical results of these devices are promising but loss of patency is not uncommon. The major difference between the two devices is the IIA component. The Cook IBD uses a -non-dedicated IIA component, while in the GORE® EXCLUDER® Iliac Branch Endoprosthesis (Gore IBE device) a dedicated self expanding stent is used. Stresses and forces exerted onto the endograft by aortic pulsatility may have an effect on the durability and functioning of the endograft. Intermittent hinchpoints could also have an effect on stent integrity and stenosis. By evaluating endograft movement during the cardiac cycle (ECG-gated CTA) it is possible to assess the stress and force exerted onto the endograft. This might help gain insight into mechanisms underlying potential endograft failure, and aid procedural planning and the development of future devices with long-term durability.

The choice for device is not part of this study.

详细描述

Objectives:To compare the mobility of the hypogastic artery during the cardiac cycle before and six weeks after implantation of the Gore IBE device in conjunction with its dedicated self expandable Internal Iliac component (Sub-study A);and to quantitatively characterize the displacement of stents with regard to the main body and native IIA during the cardiac cycle on an implanted iliac branched endograft in conjunction with a non-dedicated IIA component (Cook IBD with Advanta V12 or Fluency) with those in conjunction with a dedicated self expandable Internal Iliac component (Gore IBE device). (Sub-study B) Study design: Sub-study A & B: Multicenter observational case studies Study population: Sub-study A: 15 prospectively included patients and sub-study B: 15 patients in each group that have been treated in the period October 2006 - July 2016.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Other
盲法
None

盲法说明

The choice for the device is not part of this study and will be made by the doctor in consultation with the patient and the patients anatomy.

入排标准

性别
All
接受健康志愿者

入选标准

  • Sub-study A. scheduled endovascular aneurysm repair using the Gore IBE device.
  • Sub-study B. Patients that have been treated with an iliac branched device in the past in conjunction with either a dedicated IIA component (Gore IBE device) or non-dedicated IIA component (Cook IBD) and who are scheduled for follow-up imaging within the period July 2016-January 2017.

排除标准

  • No specific exclusion criteria. Patients will be treated according to the hospital's standard practice.

结局指标

主要结局

Mobility of hypogastric artery during cardiac cycle (sub study A)

时间窗: Up to 1 year follow-up

The mobility of the hypogastic artery during the cardiac cycle before and after implantation of the Gore IBE device (Sub-study A). This will be measured at 15 patients by making an ECG gated CTA per and postoperative.

Characterize displacement during cardiac cycle (Sub Study B)

时间窗: Up to 1 year follow-up

To quantitatively characterize the displacement during the cardiac cycle on an implanted iliac branched endograft in conjunction with a non-dedicated n balloon expandable IIA component (Cook IBD with Advanta V12 or Fluency) with those in conjunction with a dedicated self expandable Internal Iliac cComponent (Gore IBE device). (Sub-study B). This will be measured by 30 patients (15 pt Cook IBD and 15 pt Gore IBE) an ECG gated CTA postoperative.

次要结局

未报告次要终点

研究者

发起方
Rijnstate Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Michel Reijnen

Prof. Dr., Principal Investigator

Rijnstate Hospital

研究点 (3)

Loading locations...

相似试验