临床试验/NCT00631904
NCT00631904已完成不适用

SMDC Pacemaker-MRI Cohort Study

Essentia Health1 个研究点 分布在 1 个国家目标入组 150 人开始时间: 2005年1月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
150
试验地点
1
主要终点
Any change greater than 1 volt at a pulse width of 0.5 ms in a pacemaker lead 12 months from an MRI scan

研究概览

简要总结

The purpose of this study is to monitor and follow non-pacemaker dependent patients with implanted permanent pacemakers, who undergo medically required Magnetic Resonance Imaging (MRI) scans.

Patients with pacemakers are currently excluded from obtaining MRI scans. MRI scanning is now the imaging of choice for a number of neurological, vascular, or musculoskeletal conditions.

Data suggests that patients with pacemakers, when properly monitored, can safely undergo MRI scanning, though the largest published study to date consists of 54 patients, and no long term follow-up has been published.

Though MRI cardiac scanning has been demonstrated to produce local tissue heating at the pacemaker lead tip, the long term effect of tissue heating on lead stability is unclear.

This study will evaluate patients with permanent pacemakers undergoing medically indicated MRI scanning.

Patients will be followed for one year at 3, 6, and 12 months. Data collected will evaluate change in pacing thresholds over time as well as cardiac troponin I, creatinine kinase MB function, and myoglobin levels within the first 12 hours following the scans, side effects, symptoms, the need to make pacemaker program changes, and possible artifacts created by the pacemaker on the MRI scan.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Permanent pacemaker or ICD implanted for at least 6 weeks
  • Referred for medically indicated MRI
  • Age greater or equal to 18 years old

排除标准

  • ICD market released before 2001 including GDT Ventak-AV, GDT MINI-II, GDT MINI-IV, GDT MINI-III, GDT Prizm-2 MDT GEM-I series
  • Epicardial coronary sinus lead or subcutaneous array
  • Unable to program all leads to bipolar configuration
  • Pacemaker Dependent
  • Device has reached elective replacement or end of life
  • Other usual contraindications to MRI scanning
  • The use of inotropic pharmacological agents, such as dobutamine, during the MRI

结局指标

主要结局

Any change greater than 1 volt at a pulse width of 0.5 ms in a pacemaker lead 12 months from an MRI scan

时间窗: 12 months

次要结局

  • Cardiac troponin-I, creatine kinase, MB fraction, and myoglobin levels within the first 12 hours following the scans.(12 hours)