跳至主要内容
临床试验/NCT03000751
NCT03000751已完成不适用

CT Dose Optimization and Standardization Endeavor (DOSE) Collaboratory

University of California, San Francisco0 个研究点目标入组 864,080 人开始时间: 2016年7月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
864,080
主要终点
Change in Mean Effective Dose (ED)

研究概览

简要总结

This is a pragmatic stepped-wedge cluster randomized controlled trial to explore variation in doses used for diagnostic CT by pooling radiation dose data across diverse healthcare delivery systems.

To compare different strategies for lowering and optimizing dose and identify the barriers and facilitators to implementing successful dose optimization strategies and standardizing practice.

详细描述

The investigators are using a stepped-wedge cluster randomized controlled trial, collecting radiation dose information on CT from across all collaborating health care facilities, and leading several different interventions to optimize dose across facilities. In addition to collecting the CT radiation dose data, and using these results to provide feedback to the collaborating health care facilities, they will be conducting surveys of several individuals at each site, including key informants, such as lead radiologists, technologists, and medical physicist, and radiology administrators.

They will compare and identify facilitators and barriers (assessed through surveys of participating facilities) associated with successful and failed implementation of dose optimization.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Factorial
主要目的
Health Services Research
盲法
None

入排标准

年龄范围
— 至 99 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Diagnostic CT scans of the head, chest, and/or abdomen/pelvis performed within the study period

排除标准

  • non-diagnostic scans that are not of the head, chest, and/or abdomen/pelvis

结局指标

主要结局

Change in Mean Effective Dose (ED)

时间窗: Sites were randomized to 1 of 3 tracks, which determined the timing of intervention: Track A: audit at week 40, MCI at week 68 Track B: audit at week 44, MCI at week 74 Track C: audit at week 53, MCI at week 81

We will assess the change in the mean effective dose after the simple audit and multi-component interventions (MCI) in comparison to before the audit and multi-component interventions. The numbers given below reflect absolute change in mean dose (in millisieverts) relative to the baseline period.

Percentage of CT Scans With an Effective Dose Above Benchmark

时间窗: Sites were randomized to 1 of 3 tracks, which determined the timing of intervention: Track A: audit at week 40, MCI at week 68 Track B: audit at week 44, MCI at week 74 Track C: audit at week 53, MCI at week 81

We will assess the change in the percentage of examinations with an effective dose above the benchmark after the simple audit and after multi-component intervention (MCI) in comparison to doses before the audit and MCI. The benchmark for each anatomic area is defined as the 75th percentile of the dose distribution during the pre-intervention (baseline) period.

次要结局

  • Mean Dose Length Product(Sites were randomized to 1 of 3 tracks, which determined the timing of intervention: Track A: audit at week 40, MCI at week 68 Track B: audit at week 44, MCI at week 74 Track C: audit at week 53, MCI at week 81)
  • Proportion of CT Scans With a Dose Length Product Above Benchmark(Sites were randomized to 1 of 3 tracks, which determined the timing of intervention: Track A: audit at week 40, MCI at week 68 Track B: audit at week 44, MCI at week 74 Track C: audit at week 53, MCI at week 81)
  • Change in Mean Volume Computed Tomography Dose Index (CTDIvol)(Sites were randomized to 1 of 3 tracks, which determined the timing of intervention: Track A: audit at week 40, MCI at week 68 Track B: audit at week 44, MCI at week 74 Track C: audit at week 53, MCI at week 81)
  • Percentage of CT Scans With a CTDIvol Above Benchmark(Sites were randomized to 1 of 3 tracks, which determined the timing of intervention: Track A: audit at week 40, MCI at week 68 Track B: audit at week 44, MCI at week 74 Track C: audit at week 53, MCI at week 81)
  • Change in Mean Organ Doses: Brain Dose for Head CT; Lung Dose For Chest CT; Colon and Liver Dose for Abdomen CT(Sites were randomized to 1 of 3 tracks, which determined the timing of intervention: Track A: audit at week 40, MCI at week 68 Track B: audit at week 44, MCI at week 74 Track C: audit at week 53, MCI at week 81)