跳至主要内容
临床试验/NCT03326817
NCT03326817已完成不适用

A Soft Robotics Approach Towards Finger Joint Deformities in Rheumatic Diseases

National University Hospital, Singapore2 个研究点 分布在 1 个国家目标入组 8 人开始时间: 2017年10月27日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
8
试验地点
2
主要终点
Change in fingers' Total Active Motion

研究概览

简要总结

The study is to investigate the effect of a soft robotic glove approach providing continuous passive motion of fingers (flexion and extension) on degenerative arthritis patients. The approach may help reduce pain, maintain mobility and flexibility and to improve hand function.

详细描述

The aim is to investigate the effect of soft robotic gloves in providing continuous passive motion of the fingers (finger flexion and extension) of degenerative arthritis patients, for the purpose of providing pain relief and alleviating stiffness at the finger joints. Specifically, we intend to 1) observe the changes in range of motion of the fingers using the Total Active Motion (TAM) measure; 2) observe the changes in grip strength and pinch strength; and 3) record changes in the patients' perception of performance in activities of daily living using the Canadian Occupational Performance Measure (COPM).

The hypothesis is that a soft robotics approach in providing continuous passive motion of the finger joints of degenerative arthritis patients can reduce pain, maintain mobility and flexibility of the joints, and to improve hand function. The soft robotics approach and the standard hand therapy is better than the standard hand therapy alone.

The proposed soft robotic glove is capable of providing continuous passive motion (flexion and extension) of the fingers, and in addition, it is also designed to be portable and easy to operate, with minimal supervision. It is aimed at the home therapy of degenerative arthritis patients. In this study, by using the soft robotic glove and in observing changes in finger range of motion, grip and pinch strength, as well as perception of performance in daily activities. This is important in establishing this device as a viable means to ultimately slow down the progression of degenerative arthritis, and to significantly improve the patients' abilities in carrying out activities of daily living, which had been impaired by degenerative arthritis.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
30 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Aged 30-90 years regardless of race
  • Osteoarthritis of the hand (Consistent with ACR criteria 1990)
  • Ability to pay attention and maintain supported sitting for 45 mins continuously
  • Able to give own consent
  • Able to comprehend and follow commands (Abbreviated Mental Test >= 7)

排除标准

  • Inflammatory arthritis (e.g. rheumatoid arthritis), trigger fingers, carpal tunnel syndrome (by symptoms), finger contractures
  • Recent steroid injections in the wrist/hand joints within the past 3 months
  • Anti-inflammatory drugs (e.g. non-steroidal anti-inflammatory drugs or oral steroid) in the past 1 month
  • Old stroke and/or spasticity affecting the upper limbs
  • Epilepsy for the last 6 months as of the date of recruitment
  • Poor skin conditions which would hamper donning robotic gloves

研究组 & 干预措施

Control Group

Active Comparator

This group will receive standard care.

干预措施: Control Group (Other)

Soft Robotic Glove Group

Experimental

This group will receive standard care and soft robotic therapy (continuous passive motion device developed by National University of Singapore).

干预措施: Soft Robotic Glove Group (Device)

结局指标

主要结局

Change in fingers' Total Active Motion

时间窗: Week 1 baseline assessment and Week 11 post intervention assessment

Measure hand range of motion in which the sum of the extension at the metacarpophalangeal (MCP), proximal interphalangeal (PIP), and distal interphalangeal (DIP) joints is subtracted from the total achievable flexion of the same joints. Unit: Degree

Change in grip and pinch strength

时间窗: Week 1 baseline assessment and Week 11 post intervention assessment

Measure hand strength. Unit: g/kg

次要结局

  • Change in patient's Canadian Occupational Performance Measure(Week 1 baseline assessment and Week 11 post intervention assessment.)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验