Transfer Accuracy of Indirectly Bonded Orthodontic Attachments With Vacuum Formed and Silicone Transfer Trays
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 16
- 试验地点
- 2
- 主要终点
- Transfer accuracy (composite outcome) in milimetres and degrees. Which is measured on computer software.
研究概览
简要总结
The aim of this study is to comparatively investigate the performances of two different and widely used transfer trays during indirect bonding of the orthodontic braces.
详细描述
The aim of the study is to compare the accuracy of orthodontic bracket and tube transfer between double layer silicone and double layer vacuum formed trays. The sample included 368 attachments bonded in 16 patients. Each patient received one silicone and one vacuum formed tray which were randomly allocated to provide 8 trays of each type for the upper and lower arches. 3D scan data and local best-fit alignments were used to calculate the translational and rotational movements of the orthodontic attachments. Chi-square and Mann-Whitney U tests were used to compare transfer accuracy and success between the groups.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Outcomes Assessor)
入排标准
- 年龄范围
- 15 Years 至 20 Years(Child, Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •The presence of indication for both arches to be bonded in the same appointment
排除标准
- •Presence of restorations, hypoplasia or decalcification on vestibular tooth surfaces
- •Abnormal crown morphology
研究组 & 干预措施
Vacuum formed
Indirect bonding performed with the vacuum formed trays
干预措施: Indirect bonding (Device)
Silicone
Indirect bonding performed with the silicone trays
干预措施: Indirect bonding (Device)
结局指标
主要结局
Transfer accuracy (composite outcome) in milimetres and degrees. Which is measured on computer software.
时间窗: Day 0 - Day 2
The positional deviations between the attachments on the models and the mouth
次要结局
未报告次要终点
研究者
Dr. Cihan Aydoğan
Assistant prof
Yuzuncu Yıl University