跳至主要内容
临床试验/NCT05278143
NCT05278143Unknown不适用

Artificial Intelligence for Glycemic Events Detection Via Electrocardiogram in a Pediatric Population

Bambino Gesù Hospital and Research Institute1 个研究点 分布在 1 个国家目标入组 64 人开始时间: 2021年4月12日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
64
试验地点
1
主要终点
Slope across different fiducial points

研究概览

简要总结

Paediatric Type 1 Diabetes (T1D) patients are at greater risk for developing severe hypo and hyperglycaemic events due to poor glycaemic control and incorrect Insulin administration. To reduce the risk of adverse events, patients need to achieve the best possible glycaemic control through frequent blood glucose monitoring with finger prick or Continuous Glucose Monitoring (CGM) systems. However, several non-invasive techniques have been proposed aiming at exploiting changes in physiological parameters based on glucose levels. The overall objective of this study is to validate a deep learning algorithm to detect glycaemic events using electrocardiogram (ECG) signals collected through non-invasive device.

This observational single-arm study will enrol participants with T1D aged less than 18 years old who already use CGM device. Participants will wear an additional non-invasive wearable device, for recording physiological data (e.g. ECG, breathing waveform, 3-axis acceleration) for three days. ECG variables (e.g. heart rate variability features), respiratory rate, physical activity, posture and glycaemic measurements driven through ECG variables and other physiological signals (e.g. the frequency of hypo or hyperglycaemic events, the time spent in hypo- or hyperglycaemia and the time in range) are the main outcomes. A quality-of-life questionnaire will be administered to collect secondary outcomes. Data collected will be used to design, develop and validate the personalised and generalized classifiers based on a deep-learning artificial intelligence (AI) algorithm developed during the pilot study, able to automatically detect hypoglycaemic events by using few ECG heartbeats recorded with wearable devices.

This study is a validation study that will carry out additional tests on a larger diabetes sample population, to validate the previous promising pilot results that were based on four healthy adult subjects. Therefore, this study will provide evidence on the reliability of the deep-learning artificial intelligence algorithms investigators developed, in detecting glycaemic events in paediatric diabetic patients in free-living conditions. Additionally, this study aims to develop the generalized AI model for the automated glycaemic events detection on real-time ECG.

详细描述

As per inclusion criteria, the study participants continue to use their CGM device they are already using. During their routine diabetes hospital visit, the participants are asked to wear an additional wearable device, Medtronic Zephyr BioPatch, for recording the physiological data for a period of up to three days. After receiving the training session and relevant information about the study, the participants are allowed to return home with the wearable device attached. During the hospital visit, the quality of life questionnaire for paediatric patients (PEdsQL) is submitted to recruited patients. They are asked to answer questions on how T1D affects their daily activities.

During the monitoring days, patients can continue their daily activities undisturbed, without any changes in either physical activities or diet. In this way, data gathered from free-living conditions are obtained. They should wear the sensor during the day and the night and remove it while showering. The device should be approximately charged every 12-hours. For this reason, patients were provided with two devices. While wearing the second device the one used during the day should be recharged and vice versa. Patients receive regular contact from the research team not only to check on their safety and wellbeing, but also to ensure the data collection is successful. At the end of the third day, patients should return the devices to the hospital.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
4 Years 至 18 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • Age less than 18 years old
  • Diagnosed with type 1 diabetes
  • Use of continuous glucose monitoring systems (CGM)

排除标准

  • Use of standard finger prick glucometer to measure glycemic values
  • Be pregnant or becoming pregnant during the study
  • Coexistence of celiac disease
  • Coexistence of non-diabetic hypoglycemia
  • Coexistence of cardiovascular pathologies and cardiac arrhythmias

结局指标

主要结局

Slope across different fiducial points

时间窗: three days

The Slope across different fiducial points (mV/ms) is one of the Heart Rate Variability Features (HRV) that are useful to quantify the difference in ECG signals for different glycaemic events. The glycaemic events can be determined non-invasively via ECG signals by the automated AI algorithm which are trained according to glucose measurements from the CGM. The difference in ECG signals for different glycaemic events can be quantified through the difference in the slope across different fiducial points (five fiducial points (P.Q.R,S,T) and 9 intervals among them) calculated over three days of continued ECG signal registration.

Interval across different fiducial point

时间窗: three days

The interval across different fiducial points (millisecond) is one of the Heart Rate Variability Features (HRV) that are useful to quantify the difference in ECG signals for different glycaemic events. The glycaemic events can be determined non-invasively via ECG signals by the automated AI algorithm which are trained according to glucose measurements from the CGM. The difference in ECG signals for different glycaemic events can be quantified through the difference in the intervals across different fiducial points (five fiducial points (P.Q.R,S,T) and 9 intervals among them) calculated over three days of continued ECG signal registration.

Hypoglycaemic events detection

时间窗: three days

The hypoglycaemic events (identified by glycaemic values between 50mg/dl and 70mg/dl) will be indirectly detected non-invasively via ECG signals by the automated AI algorithm which are trained according to glucose measurements from the CGM. The deep-learning algorithm is able to automatically detect the hypoglycaemic events through the assessment of the ECG variables (heart rate (BPM), physical activity and posture (lying, standing, walking, running) and HRV features over three days of continued ECG and CGM signals registration.

Absolute power

时间窗: three days

The absolute power (ms\^2/Hz) is one of the Heart Rate Variability Features (HRV) that are useful to quantify the difference in ECG signals for different glycaemic events over three days of continued ECG signal registration.The signal energy can be determined for 5 minutes ECG excerpt within Ultra Low Frequency (ULF) (≤0.003 Hz), Very Low Frequency (VLF) (0.0033-0.04 Hz), Low Frequency (LF) (0.04-0.15 Hz) and High Frequency (HF) (0.15-0.4 Hz)

Hyperglycaemic events detection

时间窗: three days

The hyperglycaemic events (identified by glycaemic values between 180mg/dl and 240mg/dl) will be indirectly detected non-invasively via ECG signals by the automated AI algorithm which are trained according to glucose measurements from the CGM. The deep-learning algorithm is able to automatically detect the hyperglycaemic events through the assessment of the ECG variables (heart rate (BPM), physical activity and posture (lying, standing, walking, running) and HRV features over three days of continued ECG and CGM signals registration.

Severe hyperglycaemic events detection

时间窗: three days

The severe hyperglycaemic events (identified by glycaemic values \> 240mg/dl) will be indirectly detected non-invasively via ECG signals by the automated AI algorithm which are trained according to glucose measurements from the CGM. The deep-learning algorithm is able to automatically detect the severe hyperglycaemic events through the assessment of the ECG variables (heart rate (BPM), physical activity and posture (lying, standing, walking, running) and HRV features over three days of continued ECG and CGM signals registration.

Severe hypoglycaemic events detection

时间窗: three days

The severe hypoglycaemic events (identified by glycaemic values \< 50mg/dl) will be indirectly detected non-invasively via ECG signals by the automated AI algorithm which are trained according to glucose measurements from the CGM. The deep-learning algorithm is able to automatically detect the severe hypoglycaemic events through the assessment of the ECG variables (heart rate (BPM), physical activity and posture (lying, standing, walking, running) and HRV features over three days of continued ECG and CGM signals registration.

次要结局

  • Frequency of hyperglycaemic events(three days)
  • Time in hypoglycaemia(three days)
  • Health related quality of life(one month)
  • Glycaemic variability (GV)(three days)
  • Frequency of hypoglycaemic events(three days)
  • Time in severe hypoglycaemia(three days)
  • Glycated haemoglobin level (HbA1c)(three months)
  • Frequency of severe hypoglycaemic events(three days)
  • Frequency of severe hyperglycaemic events(three days)
  • Time in range(three days)
  • Time in hyperglycaemia(three days)
  • Time in severe hyperglycaemia(three days)

研究者

发起方
Bambino Gesù Hospital and Research Institute
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验