跳至主要内容
临床试验/NCT04629989
NCT04629989已完成不适用

The Effects of Two Systems Above Low-flow Nasal Cannula on Arterial Oxygen Tension in Patients With COVID-19 : Surgical Face Mask Versus Double-trunk Mask

Cliniques universitaires Saint-Luc- Université Catholique de Louvain1 个研究点 分布在 1 个国家目标入组 27 人开始时间: 2020年11月13日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
27
试验地点
1
主要终点
Changes in PaO2

研究概览

简要总结

This study will compare the impact of two systems above low-flow nasal cannula on the arterial oxygen tension in patients with COVID-19. The two systems are the Surgical Mask (SM) and the Double-Trunk Mask (DTM).

详细描述

Hospitalized patients with COVID-19 typically present with hypoxemia. In some patients, hypoxemia can be corrected with low flow nasal cannula. When placed above nasal cannula, some systems have demonstrated their interest in improving the performance of patient's oxygen delivery. For example, two recent studies have shown that adding a Double-Trunk Mask (DTM) or Surgical Mask (SM) above nasal cannula has the potential to improve the PaO2 despite no change in oxygen output (Duprez et al., J Clin Monit Comput 2020; Montiel et al., Ann Intensive Care 2020). However, there is no study comparing the relative effectiveness of these 2 systems.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •COVID-19 positive
  • •SpO2 between 92 and 96% with low-flow oxygen therapy
  • •Oxygen output at baseline between 3 and 7 L/min.

排除标准

  • •Pulmonary disease with hypercapnia
  • •Confusion
  • •Contra-indications to arterial blood gas sampling (peripheral arteriopathy, bleeding disorder)

研究组 & 干预措施

Low-flow nasal cannula

Active Comparator

The standard oxygen delivery system (low-flow nasal cannula) is worn by the patient, without the DTM or the SM

干预措施: Standard Oxygen Delivery System (Other)

Double-Trunk Mask

Experimental

The Double-Trunk Mask is placed above the standard oxygen delivery system (low-flow nasal cannula).

干预措施: Double-Trunk Mask (Other)

Surgical Mask

Experimental

The Surgical Mask is placed above the standard oxygen delivery system (low-flow nasal cannula).

干预措施: Surgical Mask (Other)

结局指标

主要结局

Changes in PaO2

时间窗: At baseline and 30 minutes after wearing the randomized oxygen delivery system

Oxygen tension (PaO2) in mmHg will be analyzed from a sample taken from the arterial system

次要结局

  • Change in O2 output(At 30 minutes and 60 minutes after wearing the randomized oxygen delivery system)
  • Change in pH(At baseline and 30 minutes after wearing the randomized oxygen delivery system)
  • Change in PaCO2(At baseline and 30 minutes after wearing the randomized oxygen delivery system)
  • Change in respiratory rate(At baseline, 30 minutes and 60 minutes after wearing the randomized oxygen delivery system)
  • Change in dyspnea(At baseline and 60 minutes after wearing the randomized oxygen delivery system)

研究者

发起方
Cliniques universitaires Saint-Luc- Université Catholique de Louvain
申办方类型
Other
责任方
Principal Investigator
主要研究者

Poncin

Principal Investigator

Cliniques universitaires Saint-Luc- Université Catholique de Louvain

研究点 (1)

Loading locations...

相似试验