临床试验/NCT04909190
NCT04909190已完成不适用

A Randomized Trial of an Increased Saline Flush Protocol to Reduce the Amount of Residual Air Inside a Stentgraft Delivery System

Semmelweis University Heart and Vascular Center2 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2021年6月10日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
30
试验地点
2
主要终点
Air volume

研究概览

简要总结

Non-randomized studies have shown that de-airing of the delivery system with an increased volume of saline may be associated to a decrease in periprocedural stroke during thoracic endovascular aortic repair. This study is designed to provide evidence that 4xIFU-dose volume of saline flush vs. standard IFU-dose saline flush is associated to a decrease in the amount of intra-sac air detected on the first follow-up imaging after EVAR.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • endovascular aortic repair of an abdominal aortic aneurysm using either of these devices: Terumo/Bolton Treo, Terumo Anaconda, Cook Zenith Alpha Abdominal

排除标准

  • concomitant use of an iliac bifurcation device due to insufficient common iliac landing zone on either side

结局指标

主要结局

Air volume

时间窗: within 7 days after index procedure

Total volume of air inside the aneurysm sac on discharge CT imaging.

次要结局

未报告次要终点

研究者

发起方
Semmelweis University Heart and Vascular Center
申办方类型
Other
责任方
Principal Investigator
主要研究者

Csaba Csobay-Novák MD PhD

Chief radiologist, Noninvasive Imaging

Semmelweis University Heart and Vascular Center