跳至主要内容
临床试验/NCT07198425
NCT07198425尚未招募不适用

Predicting Success of Decannulation Using Wearable-derived Physiology : A Prospective Cohort Study

Bin Zhang0 个研究点目标入组 120 人开始时间: 2026年6月2日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
发起方
入组人数
120
主要终点
Difference in physiological parameters between patients in the decannulation success and decannulation failure groups

研究概览

简要总结

The population included in this study consists of tracheostomy patients admitted to the pulmonary department of Beijing Rehabilitation Hospital, undergoing decannulation rehabilitation treatment. Once patient conditions stabilized, they were all transitioned to the decannulation process established by our department in 2018, which utilizes a speaking valve instead of capping. Each enrolled patient received physiological monitoring upon admission and the day prior to the initial use of the speaking valve, with continuous monitoring for 24 hours through wearable devices.The monitored physiological parameters were compared between the successful decannulation group and the failed decannulation group, and a predictive decannulation model was established in advance based on clinical parameters.

Decannulation criteria: If the patient can tolerate wearing the speaking valve continuously for 4 hours (gradually increasing the duration: 30 minutes, 1 hour, 2 hours, 4 hours), and if PEF > 100 liters/min, planned removal of the tracheostomy tube can be considered.

Based on decannulation outcomes, patients were categorized into the successful decannulation group and the failed decannulation group.

Successful decannulation group: Patients who successfully completed the decannulation process and had their tubes removed, with no reinsertion of the tracheostomy tube or endotracheal intubation within 48 hours after decannulation.

Failed decannulation group: Patients who did not pass the decannulation process, and the multidisciplinary team advised against removal of the tracheostomy tube; or patients who passed the decannulation process and had the tracheostomy tube removed but required reinsertion of the tracheostomy tube or endotracheal intubation within 48 hours due to medical conditions.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •18 years ≤ Age ≤ 90 years, non-mechanically ventilated patients.
  • •Tracheotomy completed, ≥48 hours since cannula placement (postoperative early edema has stabilized).
  • •Patient or legal representative has provided informed consent.

排除标准

  • •Recent (≤48 hours) major neck/upper airway surgery requiring avoidance of upper airway airflow impact.
  • •Severe consciousness disorder/delirium (RASS ≤ -3 or ≥ +2), extreme anxiety/inability to cooperate.
  • •Total laryngectomy or laryngo-tracheal separation.
  • •Oral endotracheal intubation.
  • •Age <18 years, Age > 90years.
  • •Malignant tumor with an expected survival time ≤ 6 months.
  • •Patients or legal representatives unable to obtain informed consent.
  • •Known contraindications for tracheotomy decannulation.
  • •Unable to comply with the use of wearable devices

结局指标

主要结局

Difference in physiological parameters between patients in the decannulation success and decannulation failure groups

时间窗: Monitor for 24 hours on the day of patient admission. During the 24 hours before wearing the speaking valve on the day of entering the decannulation process

Primary endpoint: Whether "decannulation success" (binary: success/failure) is achieved within 48 hours after the first planned removal of the tracheostomy tube in tracheostomized patients. Primary Objectives: Compare the differences in physiological parameters between the successful and failed decannulation groups, and integrate their respective clinical indicators to identify objective markers associated with successful extubation. Secondary Objectives: 1. Develop predictive models to assess the probability of successful decannulation prior to the procedure. 2. Investigate the relationship between time-series features (e.g., circadian rhythms, volatility) and decannulation outcomes. 3. Identify potentially modifiable physiological risk signals (e.g., nocturnal hypoxic burden, reduced heart rate variability). Wearable device data collection time: Monitoring for 24 hours after patient admission and prior to the initial use of the speaking valve.

次要结局

未报告次要终点

研究者

发起方
Bin Zhang
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Bin Zhang

Principal Investigator

Capital Medical University

相似试验