The MagnaSafe Registry: Determining the Risks of MRI in the Presence of Pacemakers and Implantable Cardioverter Defibrillators

Scripps Health21 个研究点 分布在 1 个国家目标入组 2,039 人开始时间: 2009年4月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
2,039
试验地点
21
主要终点
Rate of device failure.

研究概览

简要总结

This study will create a registry of patients with pacemakers and implantable ICDs who will undergo clinically indicated MRI and will document the incidence of any adverse events or changes in device parameters that might be associated with the procedure.

详细描述

The MagnaSafe Registry is an investigator initiated study designed to determine the risks of performing MRI for patients with pacemakers and Implantable Cardioverter-Defibrillators (ICDs). We hope that the results of the registry will provide physicians the risk-assessment data needed to assess the use of MRI as a diagnostic tool when no alternative diagnostic imaging technology is appropriate.

The number of patients living with permanent pacemakers or ICD devices in the United States is increasing dramatically as a result of expanded indications. Between 1990 and 2005, an estimated 2.8 million pacemakers and 690,000 ICDs were implanted in the United States. The number of implanted devices continues to increase without an apparent plateau.

Magnetic resonance is the imaging modality of choice for the diagnosis of many diseases of the brain, spinal cord, and musculoskeletal system. For some disease states, no acceptable alternative diagnostic imaging method is available. As the number of implanted cardiac devices is increasing, the clinical indications for MRI are expanding as well. Marketing research estimates that approximately 27.5 million MRI procedures were completed in 2007 (The Medical Information Division of IMV, LTD). It is predicted that there is a 50-75% probability that a patient with a pacemaker or ICD will have the need for an MRI over the lifetime of the device.

Most physicians consider the presence of a pacemaker or ICD to be an absolute contraindication to an MRI study. Patients are denied the examination, even when MR is clearly the superior diagnostic modality or when there is no acceptable alternative imaging test available. To provide optimal care to the increasing number of patients with an implanted cardiac device, health care professionals must have the capability to perform MR imaging with minimal risk and full knowledge of the possible complications.

The present study will create a registry of patients with pacemakers and ICDs who will undergo clinically indicated MRI and will document any adverse event or change in device parameters that may be associated with the imaging procedure. The results of this registry will provide the medical community with an accurate documentation of risk to patients and will establish a protocol of patient screening and device reprogramming for the purpose of maximizing the safe performance of MRI as a diagnostic tool in patients with implantable cardiac devices when indicated.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female 18 years or older
  • Able to provide informed consent
  • Permanent implanted pacemaker or ICD
  • Strong clinical indication for MRI; in the clinical setting where MRI is the diagnostic modality of choice for a specific disease state without acceptable alternative imaging technology as determined by the ordering physician.
  • Patient is scheduled for non-thoracic MRI (joint, extremity, brain, pelvis, cervical, and lumbar or sacral spine)

排除标准

  • Metallic objects that represent a contraindication to MR imaging, including: intra-orbital or intra-ocular retained metal fragments, and intracranial vascular clips and coils
  • Claustrophobia unresponsive to pre-procedure sedatives
  • Morbid obesity (abdominal diameter >60 cm)
  • ICD or pacemaker generator placement prior to 2002
  • ICD and pacing dependent
  • Pregnancy
  • Device generator battery voltage at elective replacement index (ERI)
  • Presence of active implantable medical device (other than pacemaker or ICD)
  • Presence of abandoned leads (with the exception of post CABG temporary epicardial pacing wires)
  • Presence of implanted cardiac device in the abdominal position
  • Pacemaker or ICD that is labeled as MRI-Conditional (approved by the FDA for exposure to MRI).

结局指标

主要结局

Rate of device failure.

时间窗: Anytime during follow up

次要结局

  • Rate of device parameter changes(Anytime during follow up)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (21)

Loading locations...