Association Between Handgrip Strength, Skinfold Thickness and Trunk Strength Among University Students
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- Trunk strength
研究概览
简要总结
The main objective was to explore relationship between skinfold measurement at multiple sites, hand grip strength, and trunk muscle strength (flexors and extensors) in healthy participants. Conclusion: There is a moderate association between hand grip strength, T score and trunk muscle strength, evident from the present research. Though no such association was seen for skinfold measurement.
详细描述
Objectives: The main objective was to explore relationship between skinfold measurement at multiple sites, hand grip strength, and trunk muscle strength (flexors and extensors) in healthy participants. Methods: Cross-sectional design, randomly recruited 40 participants. Finally only 39 participants were included. Measurements for demographic variable and anthropometric variables were done. Then the evaluation for hand grip strength and skin fold was done. Data Analysis: Quantitative variables were designated using means and standard deviations, and qualitative variables described by frequencies. The Repeated measure for Analysis of Variance (RANOVA) was used to analyse whether there was statistically significant interaction between the two groups (smoking vs non-smokers). The Pearson correlation coefficient was used to measure associations of anthropometric traits with grip strength. Multiple linear regression model was also carried to explore the linear relationship between dependent and independent variables.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 18 Years 至 25 Years(Adult)
- 性别
- Male
- 接受健康志愿者
- 是
入选标准
- •This cross-sectional study Only healthy participants with no known history of previous diseases were included (n=39).
排除标准
- •Students who found it difficult to follow the instructions for the tests after one familiarity sessions were excluded (n=0). Students reporting any kind of acute infections, previous history of chronic respiratory diseases were also excluded (n=1).
结局指标
主要结局
Trunk strength
时间窗: 1 month
Hydraulic Dynamometers (Hydraulic Dynamometer)
Handgrip strength
时间窗: 1 month
Jamar Hydraulic Dynamometers (Hydraulic Hand Dynamometer Fabrication Enterprises Inc, NY) was used as the evaluation tool for measuring grip. The handgrip measurement was carried out as per the recommendations laid by The National Institute of Health Research (NIHR)
Skinfold thickness
时间窗: 1 month
Harpenden Caliper , Skinfold thickness (SFT) at multiple marked sites on biceps, triceps, subscapular and suprailiac areas using a Harpenden Caliper (Baty, UK) for the non-dominant side. The instruments were well calibrated before testing. The measurement sites were marked, and then a minimum of two readings were taken. In case the two measurements at a particular site differed by more than 3 mm, a third measurement was taken. The mean of the two closest measurement was documented and the percentage of body fat was then calculated using the formula and table published by Durnin and Womersley
次要结局
- Smoking Habits(1 month)
- Waist Circumference(1 month)
研究者
Snehil Dixit
Assistant Professor
King Khalid University