Changes in Arch Parameters After Molar Distalization; Hybrid Hyrax Distalizer Versus Pendulum
Not Applicable
- Conditions
- Angle Class 2 Malocclusion
- Interventions
- Device: Hybrid hyrax distalizerDevice: Pendulum distalizer
- Registration Number
- NCT05470179
- Lead Sponsor
- Mohamed Abdelrhman Shendy Abdelrhman
- Brief Summary
this study was to compare the changes in arch parameters after molar distalization; hybrid hyrax distalizer versus Pendulum distalizer using CBCT.
- Detailed Description
Evaluation of maxillary molar amount of distal movement and the amount of anchorage loss Arch length, arch width, arch depth
Recruitment & Eligibility
- Status
- ENROLLING_BY_INVITATION
- Sex
- All
- Target Recruitment
- 30
Inclusion Criteria
- For group 1(Hybrid hyrax distalizer) Patients suffering maxillary collapse with a skeletal background with unilateral or bilateral posterior crossbite.
- For group 2 (Pendulum distalizer) Patients with skeletal class I or class II malocclusion who needed upper first and second molar distalization for incisor retraction or relieving of the upper arch crowding and minimum or no crowding in lower jaw were selected.
- All Patients had no systemic diseases that may affect bone quality or interfere with orthodontic treatment, periodontal disease and no previous orthodontic treatment.
- Age range was 13 to 17 years.
Exclusion Criteria
- Missed upper first molar.
- un-cooperative patient
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Pendulum distalizer device Hybrid hyrax distalizer Modified pendulum with miniscrews for 6 months for maxillary molar distal movement in class II angle malocclusion Pendulum distalizer device Pendulum distalizer Modified pendulum with miniscrews for 6 months for maxillary molar distal movement in class II angle malocclusion Hybrid hyrax distalizer Pendulum distalizer Inverted hyrax with 2 miniscrews for 6 months for maxillary molar distal movement in class II angle malocclusion Hybrid hyrax distalizer Hybrid hyrax distalizer Inverted hyrax with 2 miniscrews for 6 months for maxillary molar distal movement in class II angle malocclusion
- Primary Outcome Measures
Name Time Method Angles in degree SNA,SNB,ANB, Molar Rotation 6 months Using cbct and cast
Arch parameters in millimeter Arch length, width,depth and circumference 6 Months Assessment of airway using cbct
- Secondary Outcome Measures
Name Time Method Nasopharyngeal airway dimensions in Cubic centimeters 6 months CBCT
Trial Locations
- Locations (2)
Mohamed Shendy
🇪🇬Cairo, Nasr City, Egypt
Cairo
🇪🇬Cairo, Egypt