Accuracy of Stroke Volume Variation and Pulse Pressure Variation to Predict Fluid Responsiveness in Patients With Artificial Pneumothorax During Esophageal Surgery
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 6
- 试验地点
- 1
- 主要终点
- The area under the receiver operating characteristic (ROC) curve
研究概览
简要总结
Stroke volume variation (SVV) and pulse pressure variation (PPV) have been thought to be sensitive predictors of fluid responsiveness in mechanically ventilated participants. In this paper, the investigators reported a special group of people to use SVV and PPV during their operation. The maintenance of hemodynamic stability and the critical organ perfusion is crucial to the treatment for patients with artificial Pneumothorax during esophageal surgery, because artificial pneumothorax causes incomplete ventilation of one lung. In addition, artificial pneumothorax may seriously affect theparticipant's heart and lung function, brings more challenges to the intraoperative anesthetic management, expecially in volume management. Little information is available about the accuracy of SVV and PPV to predict fluid responsiveness in participants with artificial Pneumothorax during esophageal surgery. It is unclear whether it will affect the accuracy of SVV and PPV, and whether it will cause the change of their threshold values. The investigators will discuss it in the passage and the investigators will give an preliminary mechanism to explain the results.
详细描述
Backgroud: This study aims to evaluate the ability of stroke volume variation (SVV) and pulse pressure variation (PPV) to predict fluid responsiveness in mechanically ventilated participants with artificial Pneumothorax during esophageal surgery.
Methods: 40 participants, diagnosed with esophageal cancer, undergoing thoracoscopic radical resection of esophageal cancer were studied. All the participants used Vigileo/FloTrac system for analysis. Haemodynamic data such as MAP, HR, SV, SVI, CO, CI, SVV, PPV were recorded before and after volume expansion (VE). Fluid responsiveness was defined as an increase in SVI≥10%(△SVI≥10%). Participants were divided into Responders and Non-responders by changes in △SVI ≥10% and < 10%. Nonparametric Wilcoxon rank sum test was used to compare the hemodynamic parameters of Responders and Non-responders before and after VE. Pearson correlation analysis was used to analyze the values of SVV, PPV and △SVI. The receiver operating characteristic (ROC) curve of each hemodynamic index was drawn to determine its accuracy and threshold.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Must be arranged for thoracoscopic surgical treatment of esophageal cancer Must be mechanically ventilated with artificial Pneumothorax during the operation Must be normal in Allen test.
排除标准
- •Hypertension Coronary heart disease Arrhythmia Left ventricle ejection fractions < 50% (EF<50%) Pulmonary hypertension Congenital cardiovascular malformation Peripheral vascular disease Long-term history of oral vasoactive drugs
结局指标
主要结局
The area under the receiver operating characteristic (ROC) curve
时间窗: 1YEARS
According to the area under the curve, the predictive ability and the diagnostic thresholds of SVV and PPV were determined. The p value less than 0.05 was regarded as statistically significant.
次要结局
未报告次要终点
研究者
Yu Chen, MD
Chinese PLA General Hospital
Chinese PLA General Hospital